Mould Cultivation Cabinet
Constant temperature experiments and environmental tests for the need for humidity.
Characteristics:
- Unique internal wind circulation, fan breeze circulation.
- Large screen LCD intelligence PID, multi group data display on screen.
- The double door structure, with high quality glass easy to observe the samples, the outer door with magnetic strip, good sealing.
- The upgraded humidifying system has the advantages of small particles, good humidity uniformity and low water consumption.
BI model additional characteristics:
- LCD display 30 stage programs control, ladder operation; Imported humidity sensor module, humidity automatic control, high precision.
- Loop self diagnosis, sensor fault alarm.
Main Technical Parameters:
|
Model
|
MJX-70BIII | MJX-150BIII | MJX-250BIII | |
| MJX-70BL | MJX-150BL | MJX-250BL | ||
| Cycle Mode | Forced convection | |||
|
Function
|
Temp. range | No humidification: 0 ∼ 65°C; humidification: 10 ∼ 65°C | ||
| Temp. Resolution Ratio | 0.1°C | |||
| Temp. Motion | High Temp.: ± 0.5°C Low Temp.: ± 1°C | |||
| Temp. Uniformity | ± 1°C | |||
| Humidity Range | 50% – 90%RH | |||
| Humidity Stability | ± 5%RH | |||
|
Structure
|
Inner Chamber | Mirror Stainless Steel | ||
| Outer Shell | Cold rolling steel electrostatic spraying exterior | |||
| Insulation layer | Polyurethane | |||
| Heater | Stainless steel heater | |||
| Power rating | 0.8kW | 1.0kW | 1.2kW | |
| Compressor | Air cooled hermetic compressor | |||
| Cryogen | R134a | |||
| Defrost structure | Automatic control intelligent defrosting | |||
| Humidifying method | External | |||
| Test hole | Stainless steel inner diameter 50mm(one) | |||
| Controlled external power supply | Universal socket (one) | |||
| Temp. setting mode | Touch button setting | |||
| Temp. display mode | Measuring temperature: LCD upper row; Setting temperature: the lower row | |||
| Humidity control mode | BIII model: Manual; BL model: Auto | |||
| Timer | BIII model: 0 ∼ 99.9h BL model: 0 ∼ 99.9h x 30 Segment ( with timing wait function ) | |||
|
Operation function
|
BIII model: Fixed value operation, timing function, auto stop. | |||
| BL model: Program operation | ||||
| Sensor | PT100 | |||
| Humidity sensor | BIII model: without; BL model: with | |||
|
Additional function
|
BIII model: LED light, Deviation correction, Menu key lock, Power failure parameter memory | |||
| BL model additional character: UV light, loop self diagnosis | ||||
| Safety device | Over temperature alarm, mechanical temperature limiter | |||
|
Specification
|
Inner Chamber size(W*L*H)(mm) | 420*350*500 | 500*500*600 | 600*500*840 |
| Exterior size(W*L*H)(mm) | 580*610*1190 | 660*760*1290 | 760*760*1530 | |
| Packing size (W*L*H)(mm) | 708*716*1368 | 788*866*1468 | 888*866*1708 | |
| Volume | 70L | 150L | 250L | |
| Load per rack | 15kg | |||
| Shelf number | 9 | 12 | 18 | |
| Shelf space | 35mm | |||
| Supply (50/60Hz) Current rating | AC220V/2.3A | AC220V/3.6A | AC220V/5.5A | |
| NW/GW (kg) | 69/92 | 86/114 | 100/139 | |
| Accessory | Shelf | 2 | ||
| Optional accessories | Shelf, Touch screen controller, RS485 interface, Printer, Recorder, Remote control, Wireless SMS alarm, USB data storage |
|||