BPN-50CH(UV) Series CO2 Incubator

Category: Sort:

catalog_BPN-50CH_BPN-80CH_BPN-150CH_BPN-150CHH_BPN-190CH_BPN-190CHH_11-2_SHYH

CO2 Incubator (Infrared Sensor) — Standard Range

The new BPN series CO2 incubators are upgraded replacements for the original HH·CP series. Combining nearly twenty years of research, development and manufacturing experience in this field, they are guided by user needs and continuously incorporate newly researched technologies. Infrared CO2 sensors provide accurate, stable control unaffected by temperature and humidity.

Product Features

User-Friendly Design

  • Units can be stacked in two tiers to make full use of laboratory space. A microcomputer LCD controller provides precise, reliable control. The stainless-steel chamber and shelves have rounded corners and freely removable shelf supports for easy chamber cleaning;

Infrared Sensor

The infrared (IR) sensor rapidly monitors CO2 gas and is unaffected by fluctuations in external temperature and humidity. Even with multiple users and frequent door opening and closing, chamber CO2 concentration remains stable and uniform. Thermal-conductivity sensors, in contrast, are susceptible to temperature and humidity, have long response times and large detection errors, and require frequent calibration during long-term use;

Microbial Filter

  • The CO2 inlet is fitted with a high-efficiency microbial filter. For particles with diameters greater than or equal to 0.3μm, its filtration efficiency is up to 99.99%, effectively filtering bacteria and dust particles from the CO2 gas;

Automatic Circulating Fan Speed Control

  • Circulating fan speed is automatically controlled. When the chamber reaches a constant temperature, the speed decreases to an airflow suitable for cell growth, preventing sample evaporation caused by excessive airflow during experiments;

Door Heating System

  • The incubator door heats the inner glass door to effectively prevent condensation and the potential microbial contamination caused by it;

Safety Functions

  • An independent temperature-limit alarm system (optional) ensures safe experiments without accidents;
  • Low-temperature, high-temperature, overtemperature and prolonged door-opening alarms;

UV Sterilization System (UV Series)

  • The UV sterilization lamp at the rear top of the chamber periodically disinfects the interior, effectively killing airborne bacteria in the circulating air and water vapor from the humidification tray, thereby preventing contamination during cell culture;

Technical Specifications

Technical Specification / Model BPN-50CH(UV)
BPN-80CH(UV)
BPN-150CH(UV)
BPN-150CHH
BPN-190CH(UV)
BPN-190CHH
BPN-240CH(UV)
BPN-240CHH
BPN-30CW(UV)
BPN-80CW(UV)
BPN-150CW(UV)
Supply Voltage AC220V 50HZ
Input Power 450W/500W 750W 750W 950W 250W/680W 950W
Heating Method Air-jacketed Water-jacketed
Temperature Control Range RT+5~55°C
Ambient Operating Temperature +5~30°C
Temperature Fluctuation ±0.2°C ±0.1°C
CO2Control Range 0-20%
CO2 Control Precision ±0.1% (infrared sensor)
CO2 Recovery Time (After door opening for 30 seconds, recovery to 5%) ≤3 minutes
Temperature Recovery (After door opening for 30 seconds, recovery to 37°C) ≤8 minutes
Relative Humidity Natural evaporation ≥90%
Capacity 50L/80L 150L 190L 240L 26L/80L 150L
Chamber Dimensions (mm)
W×D×H
400×350×350
400×450×500
480×530×610 520×530×690 600×630×670 290×290×310
400×400×500
500×500×650
Overall Dimensions (mm)
W×D×H
580×450×730
590×657×870
670×710×950 708×710×1030 788×837×940 440×410×544
550×520×764
650×615×914
Shelves (Standard) 2 shelves 3 shelves 3 shelves 3 shelves 2 shelves 3 shelves
Disinfection Method UV disinfection / 90°C high-temperature, high-humidity sterilization (CHH series) UV disinfection

90°C high-temperature moist-heat sterilization system (CHH series): sterilizes the chamber, including the temperature sensor, CO2 concentration sensor, fan, shelves and supports, with high-temperature moist heat. This eliminates microbial contamination of cell cultures caused by bacteria, mold, mycoplasma and other microorganisms, providing a safe experimental environment.

Optional Accessories:

1. RS485 interface and communication software
2. Dedicated CO2 pressure-reducing regulator
3. Humidity display system
4. Independent temperature-limit controller
5. Built-in printer
6. HEPA filter

Note 1: choose either RS485/232 or printer.
Note 2: 3Q qualification and calibration services are available.
Note 3: All technical data are measured at an ambient temperature of 25°C;

Scroll to Top