PC300Pro/PCD300Pro Multi Water Quality Analyzer

PC300Pro & PCD300Pro Multi Water Quality Analyzer

Professional benchtop multi-parameter water quality analyzer supporting dual-purpose (PC300Pro: pH/ORP/Conductivity/TDS/Salinity/Resistivity/Temp) and triple-purpose (PCD300Pro: pH/ORP/Conductivity/TDS/Salinity/Resistivity/Dissolved Oxygen/Temp) testing modes with high precision and intelligent automatic compensation.

High-precision digital sensing, 1–3 point automatic calibration, automatic temperature/pressure compensation, manual salinity compensation, and versatile multi-electrode support for comprehensive laboratory water quality testing.

Applications & Target Scenarios

Application Scenarios

  • Environmental monitoring and natural water body analysis (rivers, lakes, groundwater)
  • Wastewater treatment and industrial effluent quality control
  • Aquaculture, agriculture, and hydroponic nutrient solution testing
  • Pharmaceutical, chemical, and food/beverage quality testing laboratories
  • University research, educational experiments, and routine laboratory testing

Available Models

  • PC300Pro (Dual-purpose): Measures pH, mV (ORP), Conductivity, TDS, Salinity, Resistivity, and Temperature.
  • PCD300Pro (Triple-purpose): Measures pH, mV (ORP), Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen (DO), and Temperature.

Key Features

  • Multi-Parameter Integration: Single instrument setup for multi-parameter water analysis, significantly reducing bench space and testing time.
  • Intelligent Automatic Calibration: Supports 1 to 3 points automatic pH calibration with standard buffer recognition.
  • Broad Temperature Compensation: Built-in automatic temperature compensation (ATC) across pH, conductivity, and dissolved oxygen measurement modes.
  • Comprehensive Conductivity & TDS Suite: Automatic range switching for conductivity, configurable TDS factor, and wide resistivity coverage from 5.00 Ω·cm up to 100 MΩ·cm.
  • Advanced Dissolved Oxygen Functionality (PCD300Pro): Features automatic air pressure compensation (0–200.0 kPa) and manual salinity compensation (0–45 ppt) for highly accurate DO readings.
  • Ergonomic Electrode Stand: Multi-purpose flexible electrode holder holds multiple sensors simultaneously for convenient multi-parameter dipping and testing.
  • Clear Digital LCD Display: High-contrast LCD screen clearly displays measured parameters, temperature, and calibration status.

Technical Specifications

Specification Parameter PC300Pro (Dual-purpose) PCD300Pro (Triple-purpose)
Measurement Parameters pH / mV (ORP) / Cond / TDS / Sal. / Res. / Temp pH / mV (ORP) / Cond / TDS / Sal. / Res. / DO / Temp
Overall Instrument Accuracy ±0.1% F.S ±1 digit ±0.1% F.S ±1 digit
Temperature (Temp)
Temperature Measuring Range -5.0 to 110.0 °C (23.0 to 230.0 °F) -5.0 to 110.0 °C (23.0 to 230.0 °F)
Temperature Accuracy ±0.2 °C ±0.2 °C
pH Measurement
pH Measuring Range -2.00 to 18.00 pH -2.00 to 18.00 pH
pH Resolution 0.1 / 0.01 pH 0.1 / 0.01 pH
pH Device & Overall Accuracy Device: ±0.01 pH | Accuracy: ±0.01 pH Device: ±0.01 pH | Accuracy: ±0.01 pH
pH Calibration Points 1 to 3 points automatic calibration 1 to 3 points automatic calibration
pH Temp Auto Compensation -5.0 to 110.0 °C (23.0 to 230.0 °F) -5.0 to 110.0 °C (23.0 to 230.0 °F)
ORP (mV) Measurement (Electrode Optional)
ORP Measuring Range -1999.9 to +1999.9 mV -1999.9 to +1999.9 mV
ORP Resolution 1 mV 1 mV
Electrical Conductivity / TDS / Salinity / Resistivity
Conductivity Measuring Range 0 to 200.0 mS/cm (Auto-range:
0–19.99 μS/cm, 20.0–199.9 μS/cm,
200–1999 μS/cm, 2.00–19.99 mS/cm,
20.00–199.9 mS/cm)
0 to 200.0 mS/cm (Auto-range:
0–19.99 μS/cm, 20.0–199.9 μS/cm,
200–1999 μS/cm, 2.00–19.99 mS/cm,
20.00–199.9 mS/cm)
TDS Measuring Range 0 to 100.0 g/L (Factor adjustable) 0 to 100.0 g/L (Factor adjustable)
Resistivity Measuring Range 5.00 Ω·cm to 100 MΩ·cm 5.00 Ω·cm to 100 MΩ·cm
Salinity Measuring Range 0.00 to 100.00 ppt 0.00 to 100.00 ppt
Conductivity Calibration Points 1 point 1 point
Conductivity Resolution 0.001 0.001
Conductivity Temp Compensation 0.0 to 50.0 °C (32.0 to 122.0 °F) Automatic 0.0 to 50.0 °C (32.0 to 122.0 °F) Automatic
Conductivity Accuracy ±1.0% FS ±1.0% FS
Dissolved Oxygen (DO) Measurement
DO Measuring Range Not Applicable (-) 0.00 to 20.00 mg/L
DO Accuracy Not Applicable (-) ±0.30 mg/L
Dissolved Oxygen Saturation Not Applicable (-) 0.0 to 200.0 %
DO Air Pressure Compensation Not Applicable (-) 0 to 200.0 kPa Automatic
DO Temperature Compensation Not Applicable (-) 0.0 to 50.0 °C (32.0 to 122.0 °F) Automatic
DO Salinity Compensation Not Applicable (-) 0 to 45 ppt Manual

Optional Accessories & Electrodes

Standard & Optional Sensors

  • pH Combination Electrode: Plastic-body or glass-body pH electrode with integrated temperature sensor.
  • Conductivity Probe: Platinum conductivity cell supporting low, medium, and high range testing.
  • Polarographic / Galvanic DO Probe (PCD300Pro): High-sensitivity dissolved oxygen sensor with replaceable membrane caps.
  • ORP Combination Electrode (Optional): Platinum ORP probe for oxidation-reduction potential testing.
  • Multi-Channel Flexible Electrode Stand: Holds up to 3 electrodes for simultaneous dipping and measurement.
  • pH Buffer Calibration Set: Standard pH 4.01, 7.00, 10.01 calibration solutions and conductivity standards.
Note: Please choose PC300Pro for dual pH/Conductivity testing or PCD300Pro for complete triple pH/Conductivity/Dissolved Oxygen analysis. Contact technical sales for customized electrode packages.
Scroll to Top