A130 Pr professional pH/ORP/Ion Meter

Professional pH and ion meter, 2 to 5 points calibration, setup menu contains 20 options. The meter is suitable for measuring the pH, mV, ion concentration and water hardness.

pH Mode:
• Professional pH/ion meter is equipped with a 7 inch TFT display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Solution Temperature Coefficient compensates for the pure water samples and references
the pH to 25°C.

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration Mode:
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Electrode management is capable of storing and recalling up to 3 electrode slopes.
• Selectable ion measurement methods (direct reading, known addition, known subtraction,
sample addition, sample subtraction) and concentration units (ppm, mg/L, mol/L, mmol/L).

Water Hardness Mode:
• 2 to 5 points calibration from low to high concentrations.
• Selectable measurement units (german degree, english degree, french degree, mmol/L
and mg/L) are used for professional water hardness measurements.

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Timed Interval Readings sends the measurement data to a PC or printer.
• Limit Alarm automatically alerts when reading exceeds the specified range.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Calibration report shows the date, time, calibration points, slopes and offset.
• Password protection prevents the unauthorized calibration and settings.
• Expanded memory stores or recalls up to 1000 data sets.
• Reset function automatically resumes all settings back to the factory defaults.

Specifications

Model A130
   pH
   Range -2.000 to 20.000pH
   Resolution 0.001, 0.01pH, selectable
   Accuracy ±0.002pH
   Calibration Points 1 to 5 points
   pH Buffer Options USA, NIST, DIN, 5 custom buffers
   ORP
   Range ±2000.0mV
   Resolution 0.1mV
   Accuracy ±0.2mV
   Calibration Points 1 point
   Measurement Modes Relative or absolute mV
   Ion Concentration
   Range 0.001 to 30000 (deponding on the range of ISE)
   Resolution 0.001, 0.01, 0.1, 1
   Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
   Calibration Points 2 to 5 points
   Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000
   Measurement Units ppm, mg/L, mol/L, mmol/L
   Measurement Methods Direct reading, known addition, known subtraction,
sample addition, sample subtraction
   Water Hardness
   Range (Concentration) 0.05 to 200mmol/L
   Range (German Degree) 0 to 1120°dH
   Range (English Degree) 0 to 1404°e
   Range (French Degree) 0 to 2000°fH
   Range (Ca2+) 0 to 8000mg/L
   Range (CaCO3) 0 to 19999mg/L
   Range (CaO) 0 to 11220mg/L
   Resolution 0.001, 0.01, 0.1, 1
   Accuracy ±1% F.S.
   Calibration Points 2 to 5 points
   Calibration Solutions 0.01, 0.1, 1, 10, 100mmol/L
   Temperature
   Range 0 to 105°C/32 to 221°F
   Resolution 0.1°C/0.1°F
   Accuracy ±0.5°C/±0.9°F
   Offset Calibration 1 point
   Calibration Range Reading ±10°C
   General Specifications
   Temperature Compensation 0 to 100°C/32 to 212°F, manual or automatic
   Stability Criteria Standard or high-accuracy
   Calibration Due Alarm 1 to 31 days or off
   Interval Readings 10, 30, 60 seconds, 10, 30 minutes or off
   Password Protection 4 digits
   Memory Stores up to 1000 data sets
   Output USB communication interface
   Connector BNC, 3.5mm jack socket
   Display 7” TFT LCD
   Power DC12V, using AC adapter, 220V/50Hz
   Dimensions 240(L)×220(W)×80(H)mm
   Weight 1.7kg