Bante901P portable pH/conductivity meter

Multiparameter Water Quality Meter

High-performance portable pH conductivity meter, including 4 measurement functions, the meter is suitable for outdoor measurement of pH, mV, conductivity and total dissolved solids (TDS) of samples.

Features of pH mode:
• High-performance portable pH conductivity meter with backlit LCD display.
• 1 to 5 point calibration, automatic identification of USA/NIST/DIN standard buffers.
• Automatic electrode diagnosis, display pH slope and zero offset.

Conductivity/TDS mode features:
• 1 to 5 point calibration, automatic identification of conductivity standards.
• Optional cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS conversion coefficient, linearity and pure water compensation modes.

Common features:
• Automatic temperature compensation to ensure accurate measurement of the full range.
• Automatic end point lock, keep stable readings for easy browsing and recording.
• Calibration due reminder, reminding the user to calibrate the meter regularly.
• Automatic power off, effectively saving battery power consumption.
• The setting menu can customize the number of calibration points, display resolution, stability conditions, temperature units, date and time, etc.
• Reset function, automatically restore the meter to the factory default settings.
• Expand memory, store or recall up to 500 sets of data.
• USB communication interface, easy to transfer data to a personal computer.
• Multi-mode power supply scheme (battery, power adapter, computer USB port) to ensure the smooth application of the meter.

Technical

   model Bante901P
   pH
   Measuring range -2.000~20.000pH
   display resolution 0.001, 0.01, 0.1pH, optional
   measurement accuracy ± 0.002pH
   Calibration point 1 to 5 points
   pH buffer options USA, NIST, DIN, 2 custom buffers
   mV
   Measuring range ± 1999.9mV
   display resolution 0.1, 1mV, optional
   measurement accuracy ± 0.2mV
   Conductivity
   Measuring range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
   display resolution 0.001, 0.01, 0.1, 1
   measurement accuracy ± 0.5% FS
   Calibration point 1 to 5 points
   Calibration solution 10µS, 84µS, 1413µS, 12.88mS, 111.8mS
   Temperature compensation coefficient Linear (0.0~10.0%/ ° C), pure water
   Reference temperature 20/25 ° C
   Conductivity cell constant K=0.1, 1, 10, custom
   TDS
   Measuring range 0.00~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
   display resolution 0.01, 0.1, 1
   measurement accuracy ± 1% FS
   TDS conversion factor 0.1~1.0 ( default 0.5)
   temperature
   Measuring range 0~105°C/32~221°F
   display resolution 0.1°C/0.1°F
   measurement accuracy ±0.5°C/±0.9°F
   Offset calibration 1 point, measured value ±10°C
   General parameters
   Temperature compensation range 0~100°C/32~212°F, manual or automatic
   Data lock Manual or automatic end point lock
   Stability conditions Standard or high precision
   Calibration due reminder 1 to 31 days or closed
   Automatic shut-down 10, 20, 30 minutes after no key operation
   Data storage 500 groups
   Communication output USB
   Connector BNC, 6-pin DIN, 3.5mm microphone jack
   Display screen Custom LCD display (80×60mm)
   Power type 3 AA batteries or DC5V power adapter
   Dimensions 170(L)×85(W)×30(H)mm
   Meter weight 300g
SKU: bante-900 Category: Tags: ,

Catalog

Download Catalog

Manual

Download Manual