DPH100T Series Benchtop Electrochemistry Meters

DPH100T Series Benchtop Electrochemistry Meters

Features

  • Displays pH/Cond/DO simultaneously (DPCD100T)
  • High-resolution 7-inch touch screen for easy operation
  • Operating navigation uses graphics and text
  • Automatic calibration, automatic temperature compensation, timed data logging and parameter setup
  • 1 to 5-point calibration for pH mode
  • Data storage: 500 readings/parameter
  • Data export: flash disk/PC/wireless printer (printer optional)
  • Equipped with a flexible probe holder, magnetic stirrer and standard calibration solution
  • Protection class: IP54

Single-Parameter Models — Specifications

Section Parameter Specification DPH100T DEC100T DDO100T
Parameters pH/mV, °C ✓ – –
Parameters mV (ORP), °C ✓ – –
Parameters Cond/TDS/Sal./Res., °C – ✓ –
Parameters DO, °C – – ✓
pH Measurement range (-2.000~20.000) pH ✓ – –
pH Resolution 0.01/0.001 ✓ – –
pH Accuracy ±0.002 pH ±one digit ✓ – –
pH Calibration points 1, 2, -5 pts automatic ✓ – –
pH ATC range (-10.0-135.0) °C / (14.0-275.0) °F ✓ – –
ORP Measurement range (-1999.9~+1999.9) mV ✓ – –
ORP Resolution 0.1 ✓ – –
ORP Accuracy ±0.03% F.S ±one digit ✓ – –
Conductivity Measurement range 0~2000.0 mS/cm; auto-ranging: 0~19.999 μS/cm; 20.0~199.9 μS/cm; 200~1999 μS/cm; 2.00~19.99 mS/cm; 20.00~199.9 mS/cm; 200.0~2000 mS/cm (K=10). Match test range: 0~200 mS/cm. TDS: 0~1000.0 g/L (TDS factor adjustable). Resistivity: 5.000 Ω·cm~100.0 MΩ·cm. Salinity: 0~100 ppt – ✓ –
Conductivity Calibration points One point – ✓ –
Conductivity Resolution 0.001 – ✓ –
Conductivity ATC range (-10.0-135.0) °C / (14.0-275.0) °F – ✓ –
Conductivity Accuracy ±0.5% F.S ±one digit – ✓ –
DO Measurement range (0.00~20.00) mg/L – – ✓
DO Accuracy ±0.30 mg/L – – ✓
DO DO saturation (0.0~200.0)% – – ✓
DO Automatic barometric pressure compensation (0~200.0) kPa – – ✓
DO Automatic temperature compensation (0.0~50.0) °C / (32.0~122.0) °F – – ✓
DO Manual salinity compensation 0~45 ppt – – ✓
Temperature Measurement range (-10.0~135.0) °C / (14.0~275.0) °F ✓ ✓ ✓
Temperature Accuracy ±0.2 °C ✓ ✓ ✓
Others Data export Flash disk/PC/Printer ✓ ✓ ✓
Others Power supply DC 12 V ✓ ✓ ✓

Single-Parameter Models — Test Kit

Item DPH100T DEC100T DDO100T
Meter ✓ ✓ ✓
Glass refillable combination pH probe D201G ✓ – –
Stainless-steel temperature probe DTEMP-01 ✓ – –
Glass ATC conductivity probe DCON201TG, K=1.0 – ✓ –
Polarographic DO probe DDO01-2M – – ✓
pH buffer solution: pH 4.00/7.00/10.01, 50 mL, one of each ✓ – –
Standard Cond solution: 84 μS/1413 μS/12.88 mS/cm, 50 mL, one of each – ✓ –
Membrane refill solution: DDOS-01, 30 mL, 1 bottle – – ✓
Membrane sensor caps DDOSC: 3 pcs/group, 1 package – – ✓
PC cable: 1 pc ✓ ✓ ✓
Flexible probe holder DF01: 1 pc ✓ ✓ ✓
Magnetic stirrer: 1 pc ✓ ✓ ✓
Power adaptor ✓ ✓ ✓

Multiparameter Models — Specifications

Section Parameter Specification DPC100T DPD100T DCD100T DPCD100T
Parameters pH/mV, °C ✓ ✓ – ✓
Parameters mV (ORP), °C ✓ ✓ – ✓
Parameters Cond/TDS/Sal./Res., °C ✓ – ✓ ✓
Parameters DO, °C – ✓ ✓ ✓
pH Measurement range (-2.000~20.000) pH ✓ ✓ – ✓
pH Resolution 0.01/0.001 ✓ ✓ – ✓
pH Accuracy ±0.002 pH ±one digit ✓ ✓ – ✓
pH Calibration points 1, 2, -5 pts automatic ✓ ✓ – ✓
pH ATC range (-10.0-135.0) °C / (14.0-275.0) °F ✓ ✓ – ✓
ORP Measurement range (-1999.9~+1999.9) mV ✓ ✓ – ✓
ORP Resolution 0.1 ✓ ✓ – ✓
ORP Accuracy ±0.03% F.S ±one digit ✓ ✓ – ✓
Conductivity Measurement range 0~2000.0 mS/cm; auto-ranging: 0~19.999 μS/cm; 20.0~199.9 μS/cm; 200~1999 μS/cm; 2.00~19.99 mS/cm; 20.00~199.9 mS/cm; 200.0~2000 mS/cm (K=10). Match test range: 0~200 mS/cm. TDS: 0~1000.0 g/L (TDS factor adjustable). Resistivity: 5.000 Ω·cm~100.0 MΩ·cm. Salinity: 0~100 ppt ✓ – ✓ ✓
Conductivity Calibration points One point ✓ – ✓ ✓
Conductivity Resolution 0.001 ✓ – ✓ ✓
Conductivity ATC range (0.0~50.0) °C / (32.0~122.0) °F ✓ – ✓ ✓
Conductivity Accuracy ±0.5% F.S ±one digit ✓ – ✓ ✓
DO Measurement range (0.00~20.00) mg/L – ✓ ✓ ✓
DO Accuracy ±0.30 mg/L – ✓ ✓ ✓
DO DO saturation (0.0~200.0)% – ✓ ✓ ✓
DO Automatic barometric pressure compensation (0~200.0) kPa – ✓ ✓ ✓
DO Automatic temperature compensation (0.0~50.0) °C / (32.0~122.0) °F – ✓ ✓ ✓
DO Manual salinity compensation 0~45 ppt – ✓ ✓ ✓
Temperature Measurement range (-10.0~135.0) °C / (14.0~275.0) °F ✓ ✓ ✓ ✓
Temperature Accuracy ±0.2 °C ✓ ✓ ✓ ✓
Others Data export Flash disk/PC/Printer ✓ ✓ ✓ ✓
Others Power supply DC 12 V ✓ ✓ ✓ ✓

Multiparameter Models — Test Kit

Item DPC100T DPD100T DCD100T DPCD100T
Meter ✓ ✓ ✓ ✓
Glass refillable combination pH probe D201G ✓ ✓ – ✓
Stainless-steel temperature probe DTEMP-01 ✓ ✓ – ✓
Glass ATC conductivity probe DCON201TG, K=1.0 ✓ – ✓ ✓
Polarographic DO probe DDO01-2M – ✓ ✓ ✓
pH buffer solution: pH 4.00/7.00/10.01, 50 mL, one of each ✓ ✓ – ✓
Standard Cond solution: 84 μS/1413 μS/12.88 mS/cm, 50 mL, one of each ✓ – ✓ ✓
Membrane refill solution: DDOS-01, 30 mL, 1 bottle – ✓ ✓ ✓
Membrane sensor caps DDOSC: 3 pcs/group, 1 package – ✓ ✓ ✓
PC cable: 1 pc ✓ ✓ ✓ ✓
Flexible probe holder DF01: 1 pc ✓ ✓ ✓ ✓
Magnetic stirrer: 1 pc ✓ ✓ ✓ ✓
Power adaptor ✓ ✓ ✓ ✓
Scroll to Top