Bante902 Multiparameter Meter

Bante902 Benchtop pH/Conductivity/TDS/Salinity Meter
High-precision multiparameter water quality meter contains measurement modes for pH, ORP, conductivity, TDS, salinity and resistivity, the setup menu offers 13 optional settings for customization.

pH Mode:
• Multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.

pH Mode:
• Multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.

pH Conductivity TDS Salinity Meter

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and
pure water compensations, seawater and practical salinity measurement modes.

pH Conductivity TDS Salinity Meter

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
date and time, auto-power off, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface for data transfer and timed interval readings.

   Model Bante902
   pH
   Range -2.000 to 20.000 pH
   Resolution 0.001 / 0.01 / 0.1 pH, selectable
   Accuracy ±0.002 pH
   Calibration 1 to 5 points
   pH Buffer Options USA / NIST / DIN / 2 custom buffers
   ORP
   Range -1999.9 to 1999.9 mV
   Resolution 0.1 / 1 mV, selectable
   Accuracy ±0.2 mV
   Calibration 1 point
   Measurement Modes Relative / Absolute mV
   Conductivity
   Range 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
   Resolution 0.001, 0.01, 0.1, 1, automatic
   Accuracy ±0.5% F.S.
   Calibration 1 to 5 points
   Calibration Solutions 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS
   Temperature Coefficient 0.0 to 10.0%/°C
   Pure Water Compensation Yes
   Reference Temperature 20 / 25°C
   Cell Constant K=0.1 / 1 / 10 / Custom
   TDS
   Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt
   Resolution 0.01, 0.1, 1, automatic
   Accuracy ±1% F.S.
   TDS Conversion Factor 0.1 to 1.0 (default 0.5)
   Salinity
   Range 0.00 to 80.00 ppt / 0.00 to 42.00 psu
   Resolution 0.01
   Accuracy ±1% F.S.
   Resistivity
   Range 0.00 to 20.00 MΩ
   Resolution 0.01
   Accuracy ±1% F.S.
   Temperature
   Range 0 to 105°C / 32 to 221°F
   Resolution 0.1°C/°F
   Accuracy ±0.5°C / ±0.9°F
   Calibration 1 point
   Calibration Range Reading ±10°C/°F
   Other Specifications
   Temperature Compensation 0 to 100°C / 32 to 212°F, manual or automatic
   Hold Function Manual / Auto-read measurement endpoint
   Stability Criteria Low / High
   Calibration Due Alarm 1 to 31 days or off
   Memory Stores up to 500 data sets
   Output USB communication interface
   Connector BNC, 6-pin mini-DIN, 3.5 mm jack socket
   Display Custom LCD (125 × 100 mm)
   Power Supply 5V DC power adapter
   Environmental Conditions 0 to 50°C / 32 to 122°F, relative humidity < 80%
   Dimensions 210 × 188 × 60 mm
   Weight 1.5 kg

Manual

Manual

Video