Bante900 series

Bante900 series

Multiparameter Water Quality Meter

SKU: bante-900 Category: Tag:

Description

FEATURES

pH:

  • High-accuracy laboratory meter is equipped with a large backlit, LCD display.
  • 1 to 5 points push-button calibration with auto-buffer recognition.
  • Selectable pH buffer group (USA/NIST/DIN) or using the custom calibration solutions.
  • Automatic electrode diagnosis with pH slope and offset display.

ORP:

  • 1 point offset calibration allows adjusting the displayed value to a known standard.
  • Relative and absolute millivolt modes provide the reliable ORP measurements.

ION:

  • 2 to 5 points calibration, containing the 8 concentration points can be selected.
  • Automatically recognizes the ion selective electrodes, does not need to specify type of ion.
  • Direct ion concentration readout simplifies the measurement process.
  • mV measurement mode can be used to calculate the ion concentration.
  • Selectable concentration units include the ppm, mg/L and mol/L.

CONDUCTIVITY/TDS/SALINITY/RESISTIVITY:

  • 1 to 5 points push-button calibration, automatically recognizes the calibration solutions.
  • Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.

DISSOLVED OXYGEN:

  • 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
  • Salinity and barometric pressure compensations provide the reliable measuring results.
  • Selectable measurement unit including the mg/L, ppm, mmHg and kPa.

GENERAL:

  • Automatic Temperature Compensation provides accurate reading over the entire range.
  • Calibration Due Reminder prompts user to calibrate the meter regularly.
  • Stability indicator shows when a measurement is recotnized as stable.
  • Auto-Hold features senses and locks the measurement endpoint.
  • Calibration report shows the details of the calibration standards and electrode slopes.
  • Setup menu allows setting the 15 parameters, including the number of calibration points, stability criteria, temperature unit, etc.
  • Reset feature automatically resumes all settings back to factory default options.
  • Expanded memory stores and recalls up to 500 data sets.
  • Stored readings can be transferred into the computer by USB communication interface.

MEASUREMENT PARAMETERS

  • 900 meter: pH, mV, Ion, Conductivity, TDS, Salinity, Resistivity, DO.
  • 901 meter: pH, mV, Conductivity, TDS.
  • 902 meter: pH, mV, Conductivity, TDS, Salinity, Resistivity.
  • 903 meter: pH, mV, DO.
  • 904 meter: Conductivity, TDS, Salinity, Resistivity, DO.

METER INCLUDES

  • Bante 900 meter: pH electrode, conductivity electrode, DO probe, temperature probe, pH buffers, conductivity standard solutions, DO electrolyte solution and power adapter.
  • Bante 901 or 902 meter: pH electrode, conductivity electrode, temperature probe, pH buffers, conductivity standard solutions and power adapter.
  • Bante 903 meter: pH electrode, DO probe, temperature probe, pH buffers, DO electrolyte solution and power adapter.
  • Bante 904 meter: conductivity electrode, DO probe, temperature probe, conductivity standard solutions, DO electrolyte solution and power adapter.

 

ModelBante 900Bante 901Bante 902Bante 903Bante 904
pHMeasuring Range-2.000~20.000pH****
Accuracy±0.002pH****
Calibration Points1~5 points (USA, NIST, DIN, Custom)****
mVMeasuring Range±1999.9mV****
Accuracy±0.2mV****
Calibration Points1 point (Only for Relative mV mode)***
IonMeasuring Range0.001~19999ppm, mg/L, mol/L (Depending on range of ISE)*
Accuracy± 0.5% F.S (Monovalent), ±1% F.S (Divalent)*
Calibration Points2~5 points*
ConductivityMeasuring Range0.01~20.00, 200.0, 2000µS/cm, 20.00, 200mS/cm****
Accuracy±0.5% F.S****
Calibration Points1~5 points (10, 84, 1413µS/cm, 12.88, 111.8mS/cm)****
Cell ConstantK=0.1, 1, 10 or User-defined****
Temperature CoefficientLinear and Pure water compensation****
Reference Temperature20 C or 25 C****
TDSMeasuring Range0~10.00, 100.0, 1000ppm, 10.00, 100ppt (Max. 200ppt)****
Accuracy±1% F.S****
TDS Factor0.01~1.00 (Default 0.5)****
SalinityMeasuring Range0.00~80.00ppt, 0.00~42.00psu***
Accuracy±1% F.S***
Measurement ModesPractical Salinity (psu) or Natural Seawater (ppt)***
ResistivityMeasuring Range0.00~20MΩ***
Accuracy±1% F.S***
Resolution0.01, 0.1, 1***
DOMeasuring Range0.00~20.00mg/L, 0.0~200.0% Saturation***
Accuracy±0.2mg/L,  ±2.0%***
Calibration Points1 or 2 points***
Barometric Pressure Correction60.0~112.5kPa, 450~850mmHg, Manual***
Salinity Correction0~50g/L, Manual***
GeneralTemperature Compensation0~100 C, 32~212 F, Manual or Automatic****
MemoryStores up to 500 data sets*****
OutputUSB communication interface*****
Power Requirements3×1.5V AA batteries or DC5V power adapter*****
Dimensions and Weight170(L)×85(W)×30(H)mm, 300g*****

 