High-performance portable conductivity/dissolved oxygen meter, including 5 measurement functions, the meter is suitable for outdoor measurement of sample conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.
Conductivity/TDS/salinity/resistivity mode features:
• High-performance portable conductivity/dissolved oxygen meter with backlit LCD display.
• 1 to 5 point calibration, automatic identification of conductivity standards.
• Optional cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS conversion coefficient, linearity and pure water compensation, seawater and practical
salinity measurement modes.
Dissolved oxygen mode features:
• 1 or 2 point calibration, using air-saturated water or zero oxygen liquid.
• Salinity and atmospheric pressure compensation to eliminate measurement errors.
Common features:
• Automatic temperature compensation to ensure accurate measurement of the full range.
• Automatic end point lock, keep stable readings for easy browsing and recording.
• Calibration due reminder, reminding the user to calibrate the meter regularly.
• Automatic power off, effectively saving battery power consumption.
• The setting menu can customize the number of calibration points, display resolution, stability conditions, temperature units, date and time, etc.
• Reset function, automatically restore the meter to the factory default settings.
• Expand memory, store or recall up to 500 sets of data.
• USB communication interface, easy to transfer data to a personal computer.
• Multi-mode power supply scheme (battery, power adapter, computer USB port) to ensure the smooth application of the meter.
Technical
model | Bante904P |
Conductivity | |
Measuring range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
display resolution | 0.001, 0.01, 0.1, 1 |
measurement accuracy | ±0.5% FS |
Calibration point | 1 to 5 points |
Calibration solution | 10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
Temperature compensation coefficient | Linear (0.0~10.0%/°C), pure water |
Reference temperature | 20/25°C |
Conductivity cell constant | K=0.1, 1, 10, custom |
TDS | |
Measuring range | 0.00~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
display resolution | 0.01, 0.1, 1 |
measurement accuracy | ±1% FS |
TDS conversion factor | 0.1~1.0 (default 0.5) |
salinity | |
Measuring range | 0.00~80.00ppt, 0.00~42.00psu |
display resolution | 0.01 |
measurement accuracy | ±1% FS |
Resistivity | |
Measuring range | 0.00~20.00MΩ |
display resolution | 0.01 |
measurement accuracy | ±1% FS |
Dissolved oxygen | |
Dissolved oxygen measurement range | 0.00~20.00mg/L |
display resolution | 0.01, 0.1mg/L, optional |
measurement accuracy | ±0.2mg/L |
% Saturation measurement range | 0.0~200.0% |
display resolution | 0.1, 1%, optional |
measurement accuracy | ±2.0% |
Calibration point | 1 or 2 points |
Atmospheric pressure compensation range | 60.0~112.5kPa/450~850mmHg, manual |
Salinity compensation range | 0.0~50.0g/L, manual |
temperature | |
Measuring range | 0~105°C/32~221°F |
display resolution | 0.1°C/0.1°F |
measurement accuracy | ±0.5°C/±0.9°F |
Offset calibration | 1 point, measured value ±10°C |
General parameters | |
Temperature compensation range | 0~100°C/32~212°F, manual or automatic |
Data lock | Manual or automatic end point lock |
Stability conditions | Standard or high precision |
Calibration due reminder | 1 to 31 days or closed |
Automatic shut-down | 10, 20, 30 minutes after no key operation |
Data storage | 500 groups |
Communication output | USB |
Connector | 6-pin DIN, 3.5mm microphone jack |
Display screen | Custom LCD display (80×60mm) |
Power type | 3 AA batteries or DC5V power adapter |
Dimensions | 170(L)×85(W)×30(H)mm |
Meter weight | 300g |