GR60DA Vertical Autoclave

To meet the requirements of a future lab
GR series intelligent autoclaves-a once-off selection that exempts the worries of continual upgrading

Main Features:

Heavy-gauge sterilization chamber

The heavy gauge sterilization chamber in a diameter of 40cm offers a massive space to satisfy various sterilization requirements.

Microcomputer control system

The latest “inspiration” fast-speed microcomputer intelligent control system is highly robust to not only realize the total-process controls of sterilization, but also enable convenient maintenance, inquiry, calibration, recording and upward scalability in the future. It allows three tiers of administrations, to guarantee satisfactory us and management of the autoclave.

Waste sterilization mode

Dedicated waste sterilization procedures are established for effective sterilization of lab wastes.

Drying

Thoroughly drying according to the CE standard, on hot sale in the Europe

Cooling lock OPEN temperature

Each procedure can set different cooling lock OPEN temperatures according to the thermal inertia of the sterilization object so as to prevent the user from opening the cover and hence getting burnt when the sterilization object(particularly liquid) is still in an unsafe state.

Sterilizing temperature

105-138℃

Simple and easily understandable and operable control panel

Preset Procedures and memory system

Six sterilization procedures and warming procedures are preset for the sterilizing, warming and drying of solids and liquids, the melting and warming of agars. There are up to 60 cycles and be created and saved to be readily used.

Safety

Mechanical interlocking: the unique “eight-column evenly distributed” interlocking device is safer and more reliable than common interlocking devices. The electric double inner locks enable the control system to monitor the temperature and pressure in the sterilization chamber on a real-time basis and disable opening of the sterilization chamber cover until the safe temperature and pressure are reached, hence guarantee the personal safety of the operator.

Spec GR60DR GR60DF GR60DA
GR85DR GR85DF GR85DA
GR110DR GR110DF GR110DA
Sterilization mode Solid mode:
Heating-Sterilizing-Exhausting and air cooling
YES YES YES
Solid withdrying mode:
Heating-Sterilizing-Exhaustingand air cooling-water drainage-drying
YES NO NO
Liquid mode:
Heating-sterilizing-Precooling-Steam exhausting
YES YES YES
Waste Mode:
Heating-Sterilizing-Steam exhausting and air cooling
YES YES YES
Waste Mode:Heating-Sterilizing-Steam exhausting and air cooling YES YES YES
Agar Mode:
Heating-Melting-Warming
YES YES YES
Automatic water feeding STANDARD STANDARD NO
Water level sensor STANDARD STANDARD NO
Cooling fan STANDARD STANDARD OPTIONAL
Load thermometer OPTIONAL OPTIONAL OPTIONAL
Printer OPTIONAL OPTIONAL OPTIONAL
Memory system Create 60 procedures Create 60 procedures Create 20 procedures

Specification Table

Mode GR60DA GR85DA GR110DA
GR60DF GR85DF GR110DF
GR60DR GR85DR GR110DR
Model difference DA:Standard, DF:Automatic water feeding+cooling fan, DR: DF+drying
Capacity(L) 60 85 110
Dimension(L*W*H,mm) 660x644x980(DA) 660x644x980(DA) 660x644x1180(DA)
660x831x980(DF/DR) 660x831x980(DF/DR) 660x831x1180(DF/DR)
Chamber dimension(Dia*H,mm) φ400×505 φ400×700 φ400×895
Rate power supply(w) 2900 4600 4600
Stainless steel basket(Dia*H,mm) (φ360×200)x2 (φ360×280)x2 (φ360×250)x3
Power requirement 220V,16A,50/60HZ 220V,32A,50/60HZ 220V,32A,50/60HZ
Temperature accuracy 0.1℃
Working environment 5-45℃,relatively humidity 10%-85%
Chamber material SUS 304
Sterilization temperature 105-138℃
Sterilization time range 1-6000 minutes
Melting temperature 60-100℃
Melting time range 1-6000 minutes
Warming temperature 45-60℃
Warming time range 1-9999 minutes
Drying(only for DR model) 1-300 minutes, drying temperature 80-140℃
Cooling lock OPEN temperature 40-80℃ for liquid cycle, 40-99℃ for other cycles
Sterilization cycle 1.Solid cycle 2.Liquid cycle 3.Liquid with warming cycle 4.Agar cycle 5.Solid with drying(for DR) 6. Medical waste cycle 7. Customized cycle
Sterilization cycle number DA can save up to 20 cycles, DF/DR can save up to 60 cycles
Exhaust mode Automatic internal discharging ,with a steam collecting bottle inside. Exhaust speed can be selected by 6 levels
Lid opening way Up and down
Steam collector and water tank DA: embedded 2 steam collector, DF: embedded 2 steam collector and 28L water tank  DR: embedded steam collector and 28L water tank
Preset range of timer Can be preset and auto start up to 6 days in advance
Display range of pressure gauge -0.1-0.5Mpa
Pressure Max working pressure:0.27Mpa,design pressure:0.35Mpa
Controller “Inspiration” fast speed microcomputer controller
Safety device “eight column evenly distributed” interlocking device, electric double inner locks, lid closing checking, dry scorch protection, overpressure protection, safety valve, water level sensor, over temperature protection, temperature monitor, over current and short circuit protection, leakage protection, cooling lock, anti-scald chamber cover and bench, automatic troubleshooting