RVDV-1T-H Series Touch Screen High Temperature Brinell Viscometer

Using a coaxial center structure, using a small sample adapter, each measurement requires a very small sample size, temperature control quickly and accurately. It has many measuring parameters, rich display content, convenient operation, intuitive reading, high measuring precision, stable rotational speed, strong anti-interference performance, wide working voltage and so on. can replace the same type of imported instrument.

Main features:

  1. 1. adopts ARM technology, built-in Linux system. Operation interface is simple and clear, through the creation of testing procedures and data analysis, fast and convenient viscosity testing;;
  2. Accurate viscosity measurement: each measuring range is automatically calibrated by computer with high precision and small error;
  3. Display rich: in addition to viscosity (dynamic viscosity and kinematic viscosity), there are temperature, shear rate, shear stress, measured value as a percentage of the full range value (graphic display), range overflow alarm, automatic scanning, maximum measurement range under the current rotor speed combination, date, time, etc. The kinematic viscosity can be displayed under the known density to meet the different measurement requirements of users;
  4. Fully functional: can be timed measurement, self-built 30 groups of testing procedures, access to 30 groups of measurement data, real-time display viscosity Curves, printed data, curves, etc.;
  5. Stepless speed regulation:
    RV1T series:0.3-100 rpm, a total of 998 rotational speeds

RV2T Series:0.1-200 rpm,2000 rpm

  1. Shows the curve of shear rate to viscosity: can set the range of shear rate, real-time display on the computer; can also show the curve of time to viscosity
  2. Operating System in English and Chinese

Measurable in a very large range from 50 to 80 million MPA.S, samples that can meet various high viscosity high temperature melts (e.g. hot melt adhesive, asphalt, plastics, etc.)

Optional ultra-low viscosity adapter (rotor 0) can also measure the viscosity of paraffin wax, polyethylene wax if molten sample.

Detailed Technical Parameters

model RVDV-1T-H HADV-1T-H HBDV-1T-H
Control / Display 5-inch color touch screen
speedr/min) 0.3 – 100, Stepless speed,998 speeds available
measuring range

mPa.s

6.4 3.3M

Rotor No.0:6.4-1K

Rotor No.21:50-167K

Rotor No.27:250-834K

Rotor No.28:500-1.7M

Rotor No.29:1K-3.3M

12.8 – 6.6M

Rotor No.0:12.8-1K

Rotor No.21:100-333K

Rotor No.27:500-1.7M

Rotor No.28:1K-3.3M

Rotor No.29:2K-6.6M

51.2 – 26.6M

Rotor No.0:51.2-2K

Rotor No.21:400-1.3M

Rotor No.27:2K-6.7M

Rotor No.28:4K-13.3M

Rotor No.29:8K-26.6M

Rotor 21,27,28,29(Standard)

No.0  (Optional)

Sample dosage Rotor No.0:21ml

Rotor No.21: 7.8ml

Rotor No.27: 11.3ml

Rotor No.28: 12.6ml

Rotor No.29: 11.5ml

Measurement error ±1%   (Newtonian liquid)
repetitive error ±0.5%   (Newtonian liquid)
Show shear response / shear rate have
Timing function have
Real-time display Viscosity curve Time-viscosity curve

Temperature-viscosity curve (optional temperature sensor)

(Optional data processing software shows shear rate and viscosity curves)

kinematic viscosity Density of samples to be entered
measuring range Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range
Self-built Measuring Procedures Save 30 groups (including rotor, speed, temperature, time, etc.)
Preservation of measurements Save 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.))
printer interface Print data, curves (need to buy printer)
Computer output interface RS232
working power supply Viscometer mainframe: wide voltage operation (110 V/60 Hz or 220 V/50 Hz)

Heating furnace and temperature control unit:220V50Hz

outline dimension 300 × 300 × 450(mm)
model RVDV-2T-H HADV-2T-H HBDV-2T-H
Control / Display 5-inch color touch screen
speedr/min) 0.1 – 200, Stepless speed2000 speeds available
measuring range

mPa.s

3.2 10M

Rotor No.0:3.2-1K

Rotor No.21:50-500K

Rotor No.27:125-2.5M

Rotor No.28:250-5M

Rotor No.29:500-10M

6.420M

Rotor No.0:6.4-1K

Rotor No.21:50-1M

Rotor No.27:250-5M

Rotor No.28:500-10M

Rotor No.29:1K-20M

25.680M

Rotor No.0:25.6-2K

Rotor No.21:200-4M

Rotor No.27:1K-20M

Rotor No.28:2K-40M

Rotor No.29:4K-80M

Rotor 21,27,28,29(Standard)

No.0  (Optional)

Sample dosage Rotor No.0:21ml

Rotor No.21: 7.8ml

Rotor No.27: 11.3ml

Rotor No.28: 12.6ml

Rotor No.29: 11.5ml

Measurement error ±1%   (Newtonian liquid)
repetitive error ±0.5%   (Newtonian liquid)
Show shear response / shear rate have
Timing function have
Real-time display Viscosity curve Time-viscosity curve

Temperature-viscosity curve (optional temperature sensor)

(Optional data processing software shows shear rate and viscosity curves)

kinematic viscosity Density of samples to be entered
measuring range Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range
Self-built Measuring Procedures Save 30 groups (including rotor, speed, temperature, time, etc.)
Preservation of measurements Save 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.))
printer interface Print data, curves (need to buy printer)
Computer output interface RS232
working power supply Viscometer mainframe: wide voltage operation (110 V/60 Hz or 220 V/50 Hz)

Heating furnace and temperature control unit:220V50Hz

outline dimension 300 × 300 × 450(mm)

 

Catalog