TC2000-G1/G2/G3 Thermal Cyeler (Gradient)

TC2000-G1 G2 G3 Thermal Cycler Gradient

Applications

Suitable for PCR, nucleic-acid amplification and related molecular-biology workflows.

Features

  • 10.1-inch large screen new UI interface, divided into single-channel / dual-channel / three-channel, to meet different experimental requirements
  • With advanced gradient temperature control technology, high-performance and long-lasting Peltier refrigeration and heating, which can achieve precise temperature control in zones.
  • Multi-channel module design, can run several different PCR gradient programs at the same time, to achieve multi-purpose machine
  • Self-adaptive pressure lever hot cap, close and tighten the cap in one step, can be adapted to different heights of test tubes
  • Supports up to 199 cycles to perform the next operation, and runs a countdown disc to visually display the remaining time
  • Edge temperature compensation technology for good temperature uniformity and gradient settings for easy optimisation of experimental conditions
  • Real-time display of the running status of the programme, you can set the security account and password according to customer demand
  • Automatic power failure protection, automatically execute unfinished cycles after power restoration to ensure the safe operation of the whole amplification process.
  • Hot lid temperature and hot lid operating mode can be set to meet different experimental application requirements
  • USB interface, support for U-disk storage/reading PCR data, support for U-disk software update, can be customised to meet the function of multiple file storage, support for Touch down PCR and Long PCR experiments
  • Compatible with common 0.2mL PCR tubes, PCR-8Strips and 96-well PCR plates (no skirt, half skirt)
  • Application
  • TC2000-G1/G2/G3 is an indispensable laboratory instrument in the field of molecular biology, which can be used for gene sequencing, gene cloning, gene expression, mutation, and plays an important role in various fields such as agriculture, food testing, environmental science, drug development and so on.
  • Medical Research
  • Biological ResearchGenotyping, gene cloning, species identi﹚cation, evolutionary analyses, and other studies
  • Forensic ScienceDNA analysis of crime scene samples to help identify suspects and provide a basis for public security case detection
  • IFor pathogen detection, e.g. gene identi﹚cation of viruses, bacteria and fungi, mutation analysis of disease-associated genes, gene expression analysis in cancer research, etc.
  • Agricultural sectorFor genetic research on crops and livestock, e.g. breed improvement, genetic disease detection, etc.
  • Food testingDetection of pathogenic bacteria, genetically modi﹚ed ingredients in food, etc.
  • Environmental ScienceAnalysing microbial communities in the environment and detecting genetic e﹙ects of pollutants on organisms
  • Drug DevelopmentScreening of drug targets, assessment of drug e﹙ects on gene expression
  • Genetic studiesConducting diagnosis and research on human genetic diseases
  • PalaeontologyAnalyses species identi﹚cation and classi﹚cation, development and evolution, extinction event studies and the origin of species in ancient organisms

Specifications

Specifications TC2000-G1 TC2000-G2 TC2000-G3
Sample Capacity 96×0.2mL PCR tube
12×PCR-8strips
1×0.2mL 96-well PCR plate
96×0.2mL PCR tube
12×PCR-8strips
96×0.2mL PCR tube
12×PCR-8strips
Module 1×96 2×48 3×32
Sample module
temperature control range [℃]
0-105 0-105 0-105
Hot lid temperature control range [℃] 30-115 30-115 30-115
Temperature display accuracy [℃] 0.1 0.1 0.1
Temperature control accuracy [℃] ±0.1 ±0.1 ±0.1
Temperature uniformity (at 55 ℃) [℃] ±0.2 ±0.2 ±0.2
Maximum rate of temperature change 5℃/Sec 5℃/Sec 5℃/Sec
Gradient Temp Setting Range [℃] 30-105 30-105 30-105
Gradient span [℃] 1-42℃, enter 0 to
turn off the gradient
1-25℃, enter 0 to
turn off the gradient
1-25℃, enter 0 to
turn off the gradient
Temperature Control Method Block/Tube Block/Tube Block/Tube
Material of the carrier module Aluminum Aluminum Aluminum
Display 10.1inches LCD 1280×800 10.1inches LCD 1280×800 10.1inches LCD 1280×800
Input method Touch panel Touch panel Touch panel
Power off protect Yes Yes Yes
Skip to the next step Yes Yes Yes
Communication Interface USB,WIFI USB,WIFI USB,WIFI
Number of program storage 20000+(USB FLASH) 20000+(USB FLASH) 20000+(USB FLASH)
User Defined File System Up to 30 steps and 199
cycles in a single program
Up to 30 steps and 199
cycles in a single program
Up to 30 steps and 199
cycles in a single program
Power Supply 100-240V,50/60HZ,600W 100-240V,50/60HZ,1000W 100-240V,50/60HZ,1500W
Dimensions [WxDxH] 310×422×264mm 310×422×264mm 310×422×264mm
Weight 11Kg 11Kg 11Kg
Permissible Ambient
Temperature and Humidity
5-40℃,80%RH 5-40℃,80%RH 5-40℃,80%RH

Thermal Cycler GradientTC2000-G1/G2/G3

Optional Accessories

No optional accessories are specified in the source product catalog.

Scroll to Top