600L Series Benchtop Meters

SKU: N/A Category: Sort:

GENERAL FEATURES

● Color High contrast LCD touchscreen, 7.0 inches.
● Intelligent operation system provides features including user management, calibration management, electrode management,
method management, data management and etc.
● Multi-reading feature allows auto-read, timed-read and continuous-read.
● Automatic/Manual temperature compensation ensures accurate results.
● Auto-hold feature senses and locks the measurement endpoint.
● Data capacity of up to 1000 sets for each parameter (GLPcompliant).
● Data analysis feature helps user review, compare and recalculate results.
● Data can be transferred to PC or printer by USB or RS-232 communication interfaces.
● Automation measurement.

M600L Benchtop Multi-parameter Analyzer

The multi-channel instrument allows measurements of 1, 2, 3 or 4 parameters simultaneously, either in the same or in different
samples.
● Four measurement channels can be configured in any combination.
● Support for three modules, namely pH/ISE module, conductivity module and dissolved oxygen module.
● Select from three modules to customize the four channels your way.

pH module / PH600L

● 1-6 points calibration with auto-buffer recognition.
● Selectable pH buffer groups, including NIST, DIN, GB.
● User-defined pH buffer or buffer group is supported.
● Automatic electrode diagnosis with pH slope and offset display.

Conductivity module / EC600L

● 1-5 points calibration automatically recognizes the standard solutions.
● Settable parameters, including cell constant, reference temperature (5/10/15/18/20/ 25°C), temperature compensation
coefficient and TDS factor.
● Temperature compensation type (none, linear, pure water).

ISE module / I600L

● 1-6 points calibration.
● Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, etc.
● Multi-measurement modes are supported, including Direct Reading mode,
Standard Addition mode, Sample Addition mode and GRAN mode.
● Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc.; user-defined method is supported.

DO module / DO600L

● 1 or 2 points calibration using the air-saturated water or zero oxygen
solution.
● Automatic/Manual barometric pressure compensation.
● Manual Salinity Factor Correction.

Model M600L PH600L EC600L I600L DO600L
Parameters (up to 12) pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal. /DO Saturation) pH/Temp. (mV) EC/Temp. (Resistivity/TDS/Sal.) pH/ISE/Temp. (mV/ORP/pX) DO/Temp. (DO Saturation)
pH Range -2.000 to 20.000 pH ● / ● /
Resolution 0.1, 0.01, 0.001pH ● / ● /
Accuracy ±0.002 pH ● / ● /
Calibration Points Up to 6 ● / ● /
Standard Customization Yes ● / ● /
Calibration Reminder Yes ● / ● /
Standard Recognition NIST, GB, DIN buffers ● / ● /
Slope Limit Yes ● / ● /
mV/ORP Range -2000.00 to 2000.00 mV ● / ● /
Resolution 0.1, 0.01 mV ● / ● /
Accuracy ±0.1 mV or ±0.03 % ● / ● /
EH ORP Mode Yes / / ● /
ORP Calibration Points 1~2 custom point (relative mV) / / ● /
pX Range -2.000 to 20.000 pX / / ● /
Resolution 0.1, 0.01, 0.001 pX / / ● /
Accuracy ±0.002 pX / / ● /
Calibration Points Up to 6 / / ● /
ISE Range 0~19990 / / ● /
Units mol/L, mmol/L, g/L, mg/L, μg/L / / ● /
Resolution Up to 4 significant digits / / ● /
Accuracy ±0.3 % / / ● /
Calibration Points Up to 6 / / ● /
Conductivity Range 0.000 μS/cm to 3000 mS/cm / ● / /
Resolution 0.001 μS/cm minimum; changed with range / ● / /
Accuracy ±0.5 % FS / ● / /
Reference Temperature 5, 10, 15, 18, 20, 25 ºC / ● / /
Calibration Points Up to 5 / ● / /
Calibration Reminder No / ● / /
Standard Recognition 146.5μS/cm,  1408μS/cm, 12.85mS/cm, 111.3mS/cm / ● / /
Resistivity Range 5.00 Ω·cm ~ 100.00 MΩ·cm / ● / /
Resolution 0.01 Ω·cm minimum; / ● / /
Accuracy ±0.5 % FS / ● / /
TDS Range 0.000 mg/L ~ 1000 g/L / ● / /
Resolution 0.001ppm minimum; changed with range / ● / /
Accuracy ±0.5% / ● / /
Salinity Type NaCl% / ● / /
Range (0.00 ~ 8.00)% / ● / /
Resolution 0.01% / ● / /
Accuracy ±0.1% / ● / /
Dissolved Oxygen Concentration Sensor Type Polarographic / / / ●
Range 0.00 to 99.99 mg/L / / / ●
Resolution 0.01 mg/L / / / ●
Accuracy ±0.1 mg/L / / / ●
Calibration Reminder Yes / / / ●
Calibration Points Air-saturated water or zero point / / / ●
Barometric Compensation Yes / / / ●
Manual Salinity Factor Correction Yes / / / ●
% Saturation Range (0.0 to 600)% / / / ●
Resolution 0.10% / / / ●
Accuracy ±10.0 % / / / ●
Temperature Range -5 to 130 ºC ● ● ● ●
Unit ºC ● ● ● ●
Resolution 0.1 ● ● ● ●
Accuracy ±0.1 ● ● ● ●
Measurement Reading Mode Auto Read( Fast, Medium, Slow), Timed, Continuous ● ● ● ●
Reading Prompts Reading, Stable, Locked ● ● ● ●
Temp. Compensation ATC, MTC ● ● ● ●
Data Management Data Storage 1000 Groups ● ● ● ●
GLP Features Yes ● ● ● ●
Log Management Yes ● ● ● ●
Inputs pH Electrode BNC(Q9) ● / ● /
Temp./DO Probe 6-pin MiniDIN ● ● ● ●
Temp./EC. Probe 8-pin MiniDIN / ● / /
Outputs USB,RS 232 USB 2.0 flash memory device, printer, PC ● ● ● ●
Display Options Backlight Yes ● ● ● ●
Auto Shut-down 1~60 min, off ● ● ● ●
IP Rating IP54 ● ● ● ●
Date and Time Yes ● ● ● ●
General Power AC Adapter, 100-240 VAC input, DC24V output ● ● ● ●
Dimensions 280×280×130 mm ● ● ● ●
Weight 2500g (5.51 lb) ● ● ● ●
pH Meter Type

Benchtop pH Meter

pH Measurement Mode

Conductivity / TDS / Temperature, Dissolved Oxygen / Temperature, Multi-parameter, pH / Ion / mV / Temperature

pH Resolution

0.001 pH, 0.01 pH, 0.1 pH

pH Temperature Compensation

Manual & Automatic

Scroll to Top