500T Series Benchtop Meters

SKU: N/A Categories: , Sort:

GENERAL FEATURES

● Color High contrast LCD touchscreen, 7.0 inches.
●Intelligent operation system provides features including user management, calibration management, method management,
data management and etc.
●Multi-reading feature allows auto-read, timed-read and continuous-read.
●Automatic/Manual temperature compensation ensures accurate results.
●Data storage 1000 sets for each parameter (GLP-compliant).
●Data analysis feature helps user review, compare and recalculate results.
●Support for USB or RS-232 communication.
●Reset feature automatically resumes all settings back to factory default options.
●IP54 waterproof.
●Automation measurement.

pH

● 1-6 points calibration with standard recognition.
● Selectable pH buffer groups, including DIN, NIST, USA, MERK,
JIS, GB.
● Support for pH standard group customization.
● Automatic electrode diagnosis with pH slope and offset display.

Conductivity

● 1-5 points calibration with standard recognition.
● Settable parameters, including cell constant, reference
temperature (5/10/15/18/20/ 25°C), temperature compensation
coefficient and TDS factor.
● Temperature compensation type (none, linear, pure water).

Ion

● 1-6 points calibration
● Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
● Multi-measurement modes are supported, including Direct Reading
mode, Standard Addition mode, Sample Addition mode and GRAN mode.
● Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-,NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc.; user-defined method is supported.

DO

● Support for air-saturated water or zero oxygen calibration.
● Auto barometric pressure compensation.
● Manual Salinity Factor Correction.
● Selectable pressure unit, including kPa, mbar, Torr, Atm.

Model M500T PH500T EC500T I500T DO500T
Parameters (up to 12) pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) pH/Temp. (mV/ORP) EC/Temp. (Resistivity/TDS/Sal.) pH/ISE/Temp. (mV/ORP/pX) DO/Temp. (DO Saturation)
pH Range -2.000 to 20.000 pH ● / ● /
Resolution 0.1, 0.01, 0.001pH ● / ● /
Accuracy ±0.002 pH ● / ● /
Calibration Points Up to 6 ● / ● /
Standard Customization Yes ● / ● /
Calibration Reminder Yes ● / ● /
Standard Recognition NIST,GB,DIN,USA,MERK,JIS buffers ● / ● /
Slope Limit Yes ● / ● /
mV/ORP Range -2000.00 to 2000.00 mV ● / ● /
Resolution 0.1, 0.01 mV ● / ● /
Accuracy ±0.1 mV or ±0.03 % of
reading whichever is greater
● / ● /
EH ORP Mode Yes ● / ● /
ORP Calibration Points 1 custom point (relative mV) ● / ● /
pX Range -2.000 to 20.000 pX / / ● /
Resolution 0.1, 0.01, 0.001 pX / / ● /
Accuracy ±0.002 pX / / ● /
Calibration Points Up to 6 / / ● /
ISE Range 1E-9 to 9.999E9 / / ● /
Units mol/L, mmol/L,g/L,mg/L, μg/L,ppm / / ● /
Resolution Up to 4 significant digits / / ● /
Accuracy ±0.3 % / / ● /
Calibration Points Up to 6 / / ● /
Conductivity Range 0.000 μS/cm to 2000 mS/cm / ● / /
Resolution 0.001 μS/cm minimum; changed with range / ● / /
Accuracy ±0.5 % FS / ● / /
Reference Temperature 5, 10, 15, 18, 20, 25 ºC / ● / /
Calibration Points Up to 5 / ● / /
Calibration Reminder Yes / ● / /
Standard Recognition 10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm; 12.88mS/cm / ● / /
Resistivity Range 5.00Ω·cm ~ 100.00MΩ·cm / ● / /
Resolution 0.01Ω·cm  minimum / ● / /
Accuracy ±0.5 % FS / ● / /
TDS Range 0.000 ~ 1000ppt / ● / /
Resolution 0.001ppm  minimum; changed with range / ● / /
Accuracy ±0.5% / ● / /
Salinity Type NaCl% / ● / /
Range (0.00 ~ 8.00)% / ● / /
Resolution 0.01% / ● / /
Accuracy ±0.1% / ● / /
Dissolved Oxygen Concentration Sensor Type Polarographic / / / ●
Range 0.00 to 99.99 mg/L / / / ●
Resolution 0.01mg/L / / / ●
Accuracy ±0.3mg/L(0.00 to 20.00 mg/L)
±10%(20.00 to 99.99 mg/L)
/ / / ●
Calibration Reminder Yes / / / ●
Calibration Points Air-saturated water or zero point / / / ●
Barometric Compensation Yes / / / ●
Manual Salinity Factor Correction Yes / / / ●
% Saturation Range (0.0 to 600)% / / / ●
Resolution 0.10% / / / ●
Accuracy ±10.0% / / / ●
Temperature Range -10 to 135 ºC, 14 to 275 ºF ● ● ● ●
Unit ºC,  ºF ● ● ● ●
Resolution 0.1 ● ● ● ●
Accuracy ±0.1 ● ● ● ●
Measurement Reading Mode AutoRead( Fast, Medium, Slow), Timed, Continuous ● ● ● ●
Reading Prompts Reading, Stable, Locked ● ● ● ●
Temp. Compensation ATC, MTC ● ● ● ●
Data Management Data Storage 1000 Groups ● ● ● ●
GLP Features Yes ● ● ● ●
Log Management Yes ● ● ● ●
Inputs pH Electrode BNC(Q9) ● / ● /
Temp./DO Probe 4-pin aviation connector ● / ● ●
Temp./EC. Probe 5-pin aviation connector / ● / /
Outputs USB USB 2.0 flash memory device, PC ● ● ● ●
RS 232 printer、scanner、autosampler ● ● ● ●
Display Options Backlight Yes ● ● ● ●
Auto Shut-down 1~60 min, off ● ● ● ●
IP Rating IP54 ● ● ● ●
Date and Time Yes ● ● ● ●
General Power AC Adapter,100-240 VAC input, DC24V output ● ● ● ●
Dimensions 220 x 195 x 68 mm ● ● ● ●
Weight 950g(2.09 lb) ● ● ● ●
pH Meter Type

Benchtop pH Meter

pH Measurement Mode

Conductivity / TDS / Temperature, Dissolved Oxygen / Temperature, Multi-parameter, pH / Ion / mV / Temperature

pH Resolution

0.001 pH, 0.01 pH, 0.1 pH

pH Temperature Compensation

Manual & Automatic