Catalog D-500 Homogenizer BJDL
Applications
Widely applied for histocyte lysis, cell homogenization, emulsion, nanometer scale dispersion process in biology,
pharmaceutical, genetic and pathology study, diary product or fruit homogenization, polymerization reaction,
production of fragrance, cosmetics, textile auxiliary, food, ink, paints, asphalt, fine chemicals, agricultural
chemicals, and analysis in mineral exploration, environmental protection and energy resource exploration.
Routine homogenization, emulsion,
Features
- High quality 316L stainless steel with corrosion and autoclave resistance
- Rotor with simple design can be dismounted, cleaned, and sterilized conveniently
- 6 speed levels
- Applicable for sample with viscosity up to 10000mPa·s
- Replaceable rotors and stators sharing the same shaft, cost-effective
- Automatic overload protection mechanism maximizes the working life of motor.
- Smooth motor start, stable acceleration without spillage risk
Specifications
| 36.1 23 30 40/170 | 5-25 1-5 CI,PI |
| 36.1 23 30 40/170 | 5-25 1-5 SP,PI,PT,P |
| 36.1 23 30 40/170 | 5-25 1-5 SP,PI,PT,P |
| 36.1 23 30 40/170 | 5-25 1-5 CI,C,P,F,DT,TI |
| 36.1 23 40 40/170 | High speed mixing CI,F,SP |
| 6.3 4 5 40/60 | 10-50 1-10 BT,M |
| e Analysis; PC: Petroleum Chemistry; PT: | Paper and Pulp Industry; SP: Sewage |
| ts Industry; TI: Tabacco Industry | |
| able above. Dispersion head can be moun n head can be sterilized with all usual me |
ted on the homogenizer main body and thods (including chemicals, autoclave, etc.) |
depolymerization, dispersion application
Disperse substance to form suspension and
emulsion
Disperse pigment and resin
Disperse animal or human tissue into various
solution
Facilitate the dissolve of solid substances
Sample preparation for quality control test
Animal or plant cell lysis
Emulsion, cream cosmetics, and food
formulation study
Extraction of active pharmaceutical
ingredient from pills and tablets
Specifications
components can be cleaned manually or
automatically, and can be autoclaved. Even
the precision components can be removed to
clean.
5mm Shaft
Shaft
S Stator
Ø20mm Coarse Teeth Rotor S20C
Ø30mmFine Teeth Rotor S30FØ40mm Coarse Teeth Rotor S40C
Ø20mmFine Teeth RotorS20F
Ø30mmCoarse Teeth Rotor S30C
R Rotor
Standard Rotor SR20Shear Rotor CR20Combined Rotor MR20
Standard Rotor SR30Shear Rotor CR30Combined Rotor MR30Combined Rotor MR20
Combined Rotor MR30
Emulsion RotorER20
Standard Rotor SR20
Shear RotorCR20
Combined RotorMR20
Emulsion RotorER30
Standard Rotor SR30
Shear RotorCR30
Combined RotorMR30
| DS-500/1 | Ca | t No.18201331 |
| Solid and liquid dispersion Volume 10-5000mL Max. circum. Speed 23.5m/sec General purpose Emulsion granularity range 1-10μm Suspension granularity range 10-50μm |
| DS-500/2 | Ca | t No.18201332 |
| Emulsion Volume 10-5000mL Max. circum. Speed 23.5m/sec General emulsion purpose Emulsion granularity range 1-10μm Suspension granularity range 10-50μm |
| DS-500/5 | Ca | t No.18900117 |
| Small amounts of solid and liquid dispersion Volume 1-50mL Max. circum. Speed 6.3m/sec Compatible with 5mm stator and 3.8mm rotor Special design for 1-50mL tissue homogenization, mixing and suspension in Eppendorf tube, tube strip and centrifuge tubes for clinical and diagnostic application |
| Stator & Rotor | Purpose | Working Volume |
Max. circum. Speed |
Rotor Dia. |
Stator Dia. |
Min./Max. | Granularity (μm) | Application | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Combinations | mL | m/s | mm | mm | Immersion Depth |
Suspension | Emulsion | ||||
| 18201331 | SS20CSR20 | Solid-liquid mix | 10-5000 | 23.5 | 15 | 20 | 40/170 | 10-50 | 1-10 | P,CI,PC,SD | |
| 18900205 18900215 |
S20C CR20 | Fiber | 10-5000 | 23.5 | 15 | 20 | 40/170 | 10-50 | 1-10 | SP,M,F,PT,TI | |
| 18900205 18900216 |
S20C MR20 | Solid-liquid mix | 10-5000 | 23.5 | 15 | 20 | 40/170 | 10-50 | 1-10 | CI,PI | |
| 18201332 | SS20FER20 | Emulsion | 10-5000 | 23.5 | 15 | 20 | 40/170 | 10-50 | 1-10 | SP,PI,PT,P | |
| 18900206 18900215 |
S20F CR20 | Fiber | 10-5000 | 23.5 | 15 | 20 | 40/170 | 10-50 | 1-10 | SP,BT,M,F,PT,TI | |
| 18900206 18900216 |
S20F MR20 | Solid-liquid mix | 10-5000 | 23.5 | 15 | 20 | 40/170 | 10-50 | 1-10 | CI,C,PI,F,PT,PC | |
| 18900213 18900216 |
S30C MR20 | As stirring paddle | 250-20000 | 36.1 | 15 | 30 | 40/170 | High speed mixing | CI,F,SP | ||
| 18900213 18900208 |
S30C SR30 | Solid-liquid mix | 100-8000 | 36.1 | 23 | 30 | 40/170 | 5-25 | 1-5 | SP,M,F,PT,P | |
| 18900213 18900209 |
S30C CR30 | Fiber | 100-8000 | 36.1 | 23 | 30 | 40/170 | 5-25 | 1-5 | SP,M,F,PT,P | |
| 18900213 18900229 |
S30C MR30 | Solid-liquid mix | 100-8000 | 36.1 | 23 | 30 | 40/170 | 5-25 | 1-5 | CI,PI | |
| 18900228 18900208 |
S30F SR30 | Solid-liquid mix | 100-8000 | 36.1 | 23 | 30 | 40/170 | 5-25 | 1-5 | SP,PI,PT,P | |
| 18900228 18900212 |
S30F ER30 | Emulsion | 100-8000 | 36.1 | 23 | 30 | 40/170 | 5-25 | 1-5 | SP,PI,PT,P | |
| 18900228 18900229 |
S30F MR30 | Solid-liquid mix | 100-8000 | 36.1 | 23 | 30 | 40/170 | 5-25 | 1-5 | CI,C,P,F,DT,TI | |
| 18900214 18900229 |
S40C MR30 | As stirring paddle | 1000-40000 | 36.1 | 23 | 40 | 40/170 | High speed mixing | CI,F,SP | ||
| 18900117 | SS5CSR5 | Small amount solid-liquid mix |
1-50 | 6.3 | 4 | 5 | 40/60 | 10-50 | 1-10 | BT,M |
Note:
BT: Biotech; F: Food; P: Pharmaceutics; C: Cosmetics; M: Medicine Analysis; PC: Petroleum Chemistry; PT: Paper and Pulp Industry; SP: Sewage
Treatment; CI: Ceramic Industry; CH: Chemical Industry; PI: Paints Industry; TI: Tabacco Industry
The common combinations of rotor and stator are listed in the table above. Dispersion head can be mounted on the homogenizer main body and
fixed on the holder with fixtures. All the components of dispersion head can be sterilized with all usual methods (including chemicals, autoclave, etc.)
D-500
High Shear Homogenizer
The high shear homogenizer D500 is applicable to various tasks from sample preparation to formulation study. The motor drives the rotor to rotate at high speed, and the sample is homogenized or dispersed by the gap between the rotor and stator, usually in a short period of time.
Dispersion Head Selection Guide
Material: All dispersion head components are
S DispersionShaft
ensure the mechanical performance while
rotating at high speed of 30000rpm.
Bearing: Made of excellent material, the
bearing is sturdy, durable and corrosion
resistance. Its mechanical performance and
chemical characteristics are stable.
Easy to clean: The dispersion head is designed
to be easily dismantled and thus cleaned. The
Optional Accessories
20mmStandard RotorSR20
made of high quality 316L stainless steel to