GENERAL FEATURES
● LCD display screen, 3.5 inches.
● Multi-reading feature allows auto-read, timed-read and continuous-read.
● Automatic/Manual temperature compensation ensures accurate results.
● Auto-hold feature senses and locks the measurement endpoint.
● Data capacity of up to 500 sets for each parameters (GLP-compliant).
● Support for USB communication.
● Auto-power off feature effectively extends the battery service life.
● Reset feature automatically resumes all settings back to factory default options.
● IP65 waterproof.
pH
● 1-5 points calibration with standard recognition.
● Selectable pH buffer groups, including NIST, DIN, GB.
● Automatic electrode diagnosis with pH slope and offset display.
Ion
● 1-5 points calibration.
● Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
● Measurement modes are supported, including Direct Reading mode,
Standard Addition mode, Sample Addition mode and GRAN mode.
● Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3
-, BF4
-, NH4
+, K+,
Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc.; user-defined method is supported.
Conductivity
● 1-3 points calibration with standard recognition.
● Settable parameters, including cell constant, temperature compensation
coefficient, and TDS factor.
● Temperature compensation type (none, linear, pure water).
DO
● Support for air-saturated water or zero oxygen calibration.
● Auto barometric pressure compensation.
● Manual Salinity Factor Correction.
● Selectable pressure unit, including kPa, mbar, Torr, Atm.
Model | M310F | M310F-A | PH310F | EC310F | DO310F | |
Parameters (up to 12) | pH/EC/ISE/DO/Temp. (mV/pX/Resistivity/TDS/Sal. / DO Saturation) | pH/EC/ISE/Temp. (mV/pX/Resistivity/ TDS/Sal.) | pH/Temp. (mV) | EC/Temp. (Resistivity/ TDS/Sal.) | DO/Temp. (DO Saturation) |
|
pH | Range | -2.00 to 20.00pH | ● | ● | / | / |
Resolution | 0.1, 0.01 pH | ● | ● | / | / | |
Accuracy | ±0.02 pH | ● | ● | / | / | |
Calibration Points | Up to 5 | ● | ● | / | / | |
Standard Customization | Yes | ● | ● | / | / | |
Standard Recognition | NIST, GB and DIN buffers | ● | ● | / | / | |
mV | Range | -2000.0 to 2000.0 mV | ● | ● | / | / |
Resolution | 0.1 | ● | ● | / | / | |
Accuracy | ±0.3 mV or ±0.1 % of reading whichever is greater | ● | ● | / | / | |
pX | Range | -2.00 to 20.00 | ● | / | / | / |
Resolution | 0.1, 0.01 pX | ● | / | / | / | |
Accuracy | ±0.02 pX | ● | / | / | / | |
Calibration Points | Up to 5 | ● | / | / | / | |
ISE | Range | 1E-9 to 9.999E9 | ● | / | / | / |
Units | mol/L, mmol/L,g/L,mg/L, μg/L | ● | / | / | / | |
Resolution | Up to 4 significant digits | ● | / | / | / | |
Accuracy | ±0.5 % | ● | / | / | / | |
Calibration Points | Up to 5 | ● | / | / | / | |
Conductivity | Range | 0.000 μS/cm to 500 mS/cm | ● | / | ● | / |
Resolution | 0.001 μS/cm minimum;changed with range | ● | / | ● | / | |
Accuracy | ±1.0 % FS | ● | / | ● | / | |
Reference Temperature | 20, 25 ºC | ● | / | ● | / | |
Calibration Points | Up to 3 | ● | / | ● | / | |
Standard Recognition | 84μS/cm, 1413μS/cm; 12.88mS/cm | ● | / | ● | / | |
Resistivity | Range | 5.00Ω·cm ~ 20.00MΩ·cm | ● | / | ● | / |
Resolution | 0.01Ω·cm minimum | ● | / | ● | / | |
Accuracy | ±1.0 % FS | ● | / | ● | / | |
TDS | Range | 0.00mg/L ~ 300g/L | ● | / | ● | / |
Resolution | 0.01mg/L minimum; changed with range | ● | / | ● | / | |
Accuracy | ±1.0% | ● | / | ● | / | |
Salinity | Range | (0.00 ~ 8.00)% | ● | / | ● | / |
Resolution | 0.01% | ● | / | ● | / | |
Accuracy | ±0.2% | ● | / | ● | / | |
Dissolved Oxygen Concentration | Sensor Type | Polarographic | / | / | / | ● |
Range | 0.00 to 50.00 mg/L | / | / | / | ● | |
Resolution | 0.01mg/L | / | / | / | ● | |
Accuracy | ±0.3mg/L | / | / | / | ● | |
Calibration Points | Air-saturated water or zero point | / | / | / | ● | |
Barometric Compensation | Yes | / | / | / | ● | |
Manual Salinity Factor Correction | Yes | / | / | / | ● | |
Saturation | Range | (0.0 to 300.0)% | / | / | / | ● |
Resolution | 0.1% | / | / | / | ● | |
Accuracy | ±10.0 % | / | / | / | ● | |
Temperature | Range | -5 to 110 ºC, 23 to 230 ºF | ● | ● | ● | ● |
Unit | ºC, ºF | ● | ● | ● | ● | |
Resolution | 0.1 | ● | ● | ● | ● | |
Relative Accuracy | ±0.2 | ● | ● | ● | ● | |
Measurement | Reading Mode | AutoRead( Fast, Medium, Slow), Timed, Continuous | ● | ● | ● | ● |
Reading Prompts | Reading, Stable, Locked | ● | ● | ● | ● | |
Temp. Compensation | ATC, MTC | ● | ● | ● | ● | |
Data Management | Data Storage | 500 results each | ● | ● | ● | ● |
GLP Features | Yes | ● | ● | ● | ● | |
Inputs | pH Electrode | BNC(Q9) | ● | ● | / | / |
Temp./DO Probe | 4-pin aviation connector | ● | ● | / | ● | |
Temp./EC Probe | 5-pin aviation connector | ● | / | ● | / | |
Outputs | USB | PC,printer | ● | ● | ● | ● |
Display Options | Backlight | Yes | ● | ● | ● | ● |
Auto Shut-down | 300, 600, 1200, 1800, 3600sec, off | ● | ● | ● | ● | |
IP Rating | IP65 | ● | ● | ● | ● | |
Date and Time | Yes | ● | ● | ● | ● | |
General | Power | Rechargeable Lithium batter; AC Adapter, 100-240 VAC input, DC5V output |
● | ● | ● | ● |
Dimensions | 80 x 255 x 35 mm | ● | ● | ● | ● | |
Weight | 400g(0.88 lb) | ● | ● | ● | ● |