PH-920

Benchtop pH/ORP/Ion Meter

pH Mode:

* 1 to 5 points push-button calibration with auto-buffer recognition.

* Selectable pH buffer options or using the custom calibration solutions.

* Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:

* 1 point offset calibration allows adjusting the displayed value to a known standard.

* Relative and absolute mV measurement modes provide accurate ORP readings.

Ion Concentration Mode (For PH-930):

* 2 to 5 points calibration providing the 8 concentration points can be selected.

* Automatically recognize ion electrodes, does not need to specify the type of ion.

* Selectable multiple concentration units include the ppm, mg/L and mol/L.

Others Features:

* Auto-Hold function freezes stable reading for easy viewing and recording.

* Automatic electrode diagnosis shows offset and electrode slope.

* Expanded memory stores and recalls up to 500 readings.

* Built-in real-time clock stamps stored data to meet GLP standard.

Accessories:

* PH electrode  * Temperature probe  * PH buffer pouches (pH4.01/7.00/10.01)

* USB cable    * DC5V power adapter

 

Model PH-920

 

PH-930

 

pH Range -2.000~20.000pH -2.000~20.000pH
pH Accuracy ±0.002pH ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1~5 points 1~5 points
Calibration Solutions USA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75) or User-defined USA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75) or User-defined
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic 0~100°C, 32~212°F, Manual or Automatic
mV Range -1999.9~1999.9mV -1999.9~1999.9mV
mV Accuracy ±0.2mV ±0.2mV
Resolution 0.1, 1mV, Selectable 0.1, 1mV, Selectable
Calibration Points 1 point (Only for Relative mV mode) 1 point (Only for Relative mV mode)
Ion Concentration Range —– 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)
Ion Concentration Accuracy —– ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
Temperature Range 0~105°C, 32~221°F —–
Temperature Accuracy ±0.5°C, ±0.9°F —–
Calibration Points 2~5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L)
Memory Stores up to 500 data sets Stores up to 500 data sets
Output USB Communication Interface USB Communication Interface
Connector BNC —–
Power Requirements DC5V/400mA power adapter
Dimensions(mm) 210*188*60mm
Weight(kg) 1.5kg
Package Size(W*D*H)mm 310*240*180mm
Gross weight(kg) 1.7kg

 

SKU: PH-920 Categories: , Tag: