Full Automatic Ethylene Oxide Sterilizer

Full automatic ethylene oxide sterilizer is a 100% ethylene oxide gas for the sterilization of media used for sterilization of damp heat sensitive items,such as surgical  precision medical equipment,optical instrumens,electronic equipment,plastic products and vari-ous medical supplies,etc, for plastic, metal and rubber materials  will not produce any cor-rosion. Ethylene oxide sterilization is the most effective way of gas sterilization are known,with broad-spectrum  sterilization, strong  penetrability, no damage to the items and  environme-nt.It has perfect & reliable chemical and biological test,easy to storage sterilization items.

It is the hospital necessary lowtemperature sterilization equipment. Whether it is in the supply room, the operation

room or the specialist clinic,ethylene oxide sterilization machine is all you need to safe,reliable & easy to operate

low temperature sterilization equipment.

Hysteroscopy,laparoscopy,laryngoscope,probe,rigid endoscope,hose endoscope,ophthalmic lens,fiber optic

cables,intracranial pressure sensor,cryotherapy probe,resection of the prostate,esophageal dilator,electocautery

apparatus,defibrillation electrode,laser head,metal,glass,silica gel,rubber Chinese medicine,western medicine,

human implant, DNA,etc.

 

Model BKEO2C-120 BKEO2C-190
Volume(L) 120L 190L
Sterilizing Room Size(L*W*H)cm 70*45*40 82*51*46
Outline Dimension 108*80*171 108*80*171
Net Weight 248Kg 319kw
Power Connection 2.95W 3.15kw
Control Mode Programmable controller,a key start to the end,automatic completion
Sterilization Method 100%ethylene oxide gas sterilization
Ddisplay Mode Touch screen real-time display of the main parameters,operating procedures

and ope-rating conditions,etc.

Drug Add Method Built-in piercing type automatic dosin
Sterilization Chamber Volume ≥120L    190L
Sterilization Room Material 5052Aluminum or 304stainless steel
Sterilization Chamber Seal High performance,high temperature resistant imported silicone material

se-aling ring

Sterilization Room Door Automatically lock the door after the device is started,the end of  the program

automatically opens, effectively prevent the misoperation

Humidity The electric heat tracing system,temperature is more even precision
Ethylene Oxide Concentration 0.6g/L
Sterilization And Exhaust Time 0-99 hours free set, the entire cycle time is 6-12h
Safety Requirements 1.Unexpected power failure,sterilizere restore the stop state automatically

2.The whole process of negative pressure oper-ation,ensure the epoxy ethane

zero leakage

Fault And Error Handling If there is a fault or error, there is sound and light alarm,can immediately stop

operation, color LCD touch screen with Chinese display and record

Control Valve Germany imported components
Humidity Control Automatic humidification, built in inlet humidity sensor
Leakage Detection Microcomputer automatic detecion,such as leakage automatically turned into

the exhaust state,and the alam

Ga Medical epoxy ethane gas
Record / Print Can detailed records and Chinese printing operation of the data,can be used

for permanent preservation.

Emissions Way 1.Built-in water atomization splitter.2.EO is converted to ethylene glycol,which

effectively reduces the degree of  pollution to the environment.3.Can choose

the sewer discharge

Network Interface Provided free of charge back software interface connection data service and

is responsible for the connection

Installation, After Sale, Maintenance 1. Equipment warranty for one year,the warranty pe-riod all the axpenses shall be borne by the manufac-turer

2. 24hours after sale telephone response mech-anism

3. The company is responsible for guide inst-alltion,training the operator

 

 