Description

Multiparameter laboratory salinity meter contains 5 measurement modes, the meter is suitable for measuring the conductivity, TDS, salinity, resistivity and conductviity ash. Accuracy: 1% F.S.

Feature:
• Multiparameter laboratory salinity meter is equipped with a 7 inch TFT display.
• 1 to 5 points push-button calibration, automatically recognizes the calibration solutions.
• Selectable cell constant is matched the connected conductivity electrode and recalled the
calibration data.
• Selectable linear temperature compensation coefficient (%/°C ), pure water compensation
coefficient, reference temperature and TDS conversion factor.
• Automatic Temperature Compensation corrects the conductivity measurement to selected
reference temperature.

• Limit alarm alerts when reading exceeds range.
• Calibration Due Alarm prompts user to calibrate the meter regularly.
• Calibration report provides the details of the calibration standard and cell constant.
• Stability indicator shows when a measurement is recognized as stable.
• Auto-Read feature senses and locks the measurement endpoint.
• Interval Readings automatically send the measured data to the computer or printer.
• Password protection prevents the unauthorized calibration and settings.
• Expanded memory stores and recalls up to 1000 data sets.
• Stored readings can be transferred into the computer by USB communication interface.
• Reset feature automatically resumes all settings back to factory default option

 

   ModelA150
   Conductivity
   Range0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
   Accuracy±0.5% F.S
   Resolution0.001, 0.01, 0.1, 1
   Calibration Points1 to 3 points
   Calibration Solutions10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
   TDS
   Range0.00mg/L~100.0g/L (Max. 200g/L)
   Accuracy±1% F.S
   Resolution0.01, 0.1, 1
   TDS Factor0.01~1.00 (Default 0.5)
   Salinity
   Range0.00~80.00ppt, 0.00~42.00psu, 0.00~8.00%
   Accuracy±1% F.S
   Resolution0.01, 0.1, 1
   Measurement ModesPractical salinity (psu), Natural seawater (ppt) or %
   Resistivity
   Range0.00~30.00MΩ
   Accuracy±1% F.S
   Resolution0.01, 0.1, 1
   Conductviity Ash
   Range0.00~100%
   Accuracy±1% F.S
   Measurement ModesRefined sugar or Raw sugar
   Temperature
   Range0~105°C, 32~221°F
   Accuracy±0.5°C
   Resolution0.1°C, 0.1°F
   Calibration Points1 point
   Calibration RangeMeasured value ±10°C
   General
   Temperature Compensation0~100°C, 32~212°F, Manual or Automatic
   Temperature CoefficientLinear, Non-linear or Pure water compensation
   Reference Temperature20°C or 25°C
   Cell Constant2-pole electrodes (K=0.1, 1, 10) or 4-pole electrode
   Stability CriteriaStandard or High-accuracy
   Interval Readings10, 30, 60 seconds, 10, 30 minutes or Off
   Calibration Due Alarm1 to 31 days or Off
   MemoryStores up to 1000 data sets
   OutputUSB communication interface
   Connector6-pin mini plug
   Display7 inch TFT LCD
   PowerDC12V, using AC adapter, 220VAC/50Hz
   Dimensions240(L)×220(W)×80(H)mm
   Weight1.7kg

Search