GM Series Diaphragm Vacuum Pump

GM Series Diaphragm Vacuum Pump

Products Instroduction

“JT” Series Diaphragm Vacuum Pump has the features of continuous oil free pumping , low noise level , higher efficiency , long lifetime . It is mainly used in medicinal products analysis , industry of fine chemicals , biochemical pharmacy , food examination , The criminal investigation technology , etc . It is used with the precision chromatography instrument , the necessary of laboratory . This product is specially designed for laboratory , reliable and easy to use . These series of products have obtained the national patent .

Application:

Vacuum adsorption
Solvent filtration
Vacuum distillation
Vacuum drying
Compressing and converting gas
SPE (solid phase extraction)Deaeration

Features:

1.The product could work without any medium and does not produce pollution .The gas exchange room is placed with filtering material , to ensure that the air is clean .
2.New material and new technology are adopted in production . It is convenient to move , and work smoothly , thus ensuring the ideal vacuum degree and higher air velocity .
3.Using frictionless membrane body movement , does not produce heat , no friction consumption . Imported rubber diaphragm has corrosion resistance and long service life .
4.Automatic cooling exhaust system is designed in the body , ensures continuous operation 24 hours a day .
5.The pressure adjustable design can satisfy a certain range of vacuum and gas velocity .
6.Bearing imported classic bearing , smooth operation , low noise , high efficiency .
7.The parts in contact with the gas of anticorrosive pump is with TEFLON surface treatment , which have complete ability of resistance to chemical corrosion .
8.Special motor is ODM provided by the export of professional motor manufacturer and has got the European CE certification . It has the reasonable rotation design , equipped with a power overheat protector , when the pump body temperature reached 130 degrees , it will automatically power off , to protect the motor from being damaged in the long running work .
9.Small volume and light weight , easy to move , save space , convenient repair and maintenance .

Diaphragm Vacuum Pump –Anticorrosive

New anticorrosive pumps through Teflon treatment have been launched in market . Teflon treatment is accessible to all types of Jinteng pumps .
Anticorrosive pump is through Teflon treatment , the parts which contact with the gas are PTFE material , it’s suitable for the corrosive chemical , pharmaceutical , petrochemical gases etc . It’s used for vacuum filtration , reduced pressure distillation , rotary evaporation , vacuum concentration , centrifugal concentration , solid phase extraction etc . It’s a very high cost performance product with quality reliability , unique structural design to meet the various needs of the laboratory . The specifications are same as the normal pump .

New PTFE Anticorrosive Pump Will Come Into the Market

FEATURES :

1.Corrosion resistance , able to tolerance almost all strong acid (including aqua regia), strong alkali , strong oxidizer , reductant , and variety of organic solvents .
2.Withstand high and low temperatures , can be used in temperature of -190℃ to 260℃ .
3.Non-stick surface , most solid material and impurity particles can not conglutinate on the surface .

Technological competitiveness

The internal components of Jinteng diaphragm vacuum pump series are produced by numerical control equipments which imported from Germany DMG and Korea kia . This is our unique technology competitiveness that all the same type of products made by other companies could not match . With the good appearance , stable quality , excellent performance of our products , and high quality service of our company , we believe that Jinteng’s diaphragm vacuum pump is the best choice for your laboratory .

GM-0.20
Speed of evacuation (L/Min ): 12
Ultimate pressure vacuum : ≥0.075 Mpa 250 mbar
Voltage rating :220Vac, 50Hz
Motor power (w): 75W
Pressure : ≥30Psi
Inlet (mm): Ø 6
Outlet (mm): Ø 6
Temperature of working environment (℃ ): 7-40
Function : Vacuum & Pressure
Pump head : Nylon
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 195 x 98 x 156
Noise level (DB ): <60
Weight (kg ): 4

GM-0.33A (GM-0.33II)
Speed of evacuation (L/Min ): 20
Ultimate pressure vacuum : ≥0.08 Mpa 200 mbar
Voltage rating :220Vac, 50Hz
Motor power (w): 160W
Inlet (mm): Ø 6
Outlet (mm):Inner Silencer
Temperature of working environment (℃ ): 7-40
Function : Vacuum
Pump head : 1
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 215 x 120 x 235
Noise level (DB ): <60
Weight (kg ): 7.5
Diaphragm : NBR
Valves : NBR

GM-0.5A (GM-0.5)
Speed of evacuation (L/Min ):30
Ultimate pressure vacuum : ≥0.08 Mpa 200 mbar
Voltage rating :220Vac, 50Hz
Motor power (w):160W
Pressure : ≥30Psi
Inlet (mm): Ø 6
Outlet (mm): Ø 6
Temperature of working environment (℃ ): 7-40
Function : Vacuum & Pressure
Pump head : 1
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 210 x 160 x 235
Noise level (DB ): <60
Weight (kg ): 8
Diaphragm : NBR
Valves : NBR

GM-0.5B (GM-0.5II)
Speed of evacuation (L/Min ):30
Ultimate pressure vacuum : ≥0.095 Mpa 50 mbar
Voltage rating :220Vac, 50Hz
Motor power (w): 160W
Inlet (mm): Ø 6
Outlet (mm): Silencer
Temperature of working environment (℃ ): 7-40
Function : Vacuum
Pump head : 2
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 300 x 120 x 235
Noise level (DB ): <60
Weight (kg ): 10
Diaphragm : NBR
Valves : NBR

GM-1.0A (GM-1.0)
Speed of evacuation (L/Min ):60
Ultimate pressure vacuum : ≥0.08 Mpa 200 mbar
Voltage rating :220Vac, 50Hz
Motor power (w): 160W
Pressure : ≥30Psi
Inlet (mm): Ø 6
Outlet (mm): Ø 6
Temperature of working environment (℃ ): 7-40
Function : Vacuum & Pressure
Pump head : 2
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 300 x 160 x 235
Noise level (DB ): <60
Weight (kg ): 10
Diaphragm : NBR
Valves : NBR

GM-0.33A-AT (GM-0.33II-AT)
Speed of evacuation (L/Min ): 20
Ultimate pressure vacuum : ≥0.08 Mpa 200 mbar
Voltage rating :220Vac, 50Hz
Motor power (w): 160W
Inlet (mm): Ø 6
Outlet (mm):Inner Silencer
Temperature of working environment (℃ ): 7-40
Function : Vacuum
Pump head : 1
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 215 x 120 x 235
Noise level (DB ): <60
Weight (kg ): 7.5
Diaphragm : NBR
Valves : NBR

GM-0.5A-AT (GM-0.5-AT)
Speed of evacuation (L/Min ):30
Ultimate pressure vacuum : ≥0.08 Mpa 200 mbar
Voltage rating :220Vac, 50Hz
Motor power (w):160W
Pressure : ≥30Psi
Inlet (mm): Ø 6
Outlet (mm): Ø 6
Temperature of working environment (℃ ): 7-40
Function : Vacuum & Pressure
Pump head : 1
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 210 x 160 x 235
Noise level (DB ): <60
Weight (kg ): 8
Diaphragm : NBR
Valves : NBR

GM-0.5B-AT (GM-0.5II-AT)
Speed of evacuation (L/Min ):30
Ultimate pressure vacuum : ≥0.095 Mpa 50 mbar
Voltage rating :220Vac, 50Hz
Motor power (w): 160W
Inlet (mm): Ø 6
Outlet (mm): Silencer
Temperature of working environment (℃ ): 7-40
Function : Vacuum
Pump head : 2
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 300 x 120 x 235
Noise level (DB ): <60
Weight (kg ): 10
Diaphragm : NBR
Valves : NBR

GM-1.0A-AT (GM-1.00-AT)
Speed of evacuation (L/Min ):60
Ultimate pressure vacuum : ≥0.08 Mpa 200 mbar
Voltage rating :220Vac, 50Hz
Motor power (w): 160W
Pressure : ≥30Psi
Inlet (mm): Ø 6
Outlet (mm): Ø 6
Temperature of working environment (℃ ): 7-40
Function : Vacuum & Pressure
Pump head : 2
Temp of the body (℃ ): <55
Dimensions (LXBXH )(mm): 300 x 160 x 235
Noise level (DB ): <60
Weight (kg ): 10
Diaphragm : NBR
Valves : NBR

JT300 anti Back Suction Device:

 

 

 

 

 

 

 

 

 

 

 

 

 

Outer diameter: 6.8cm
Height: 18.5cm
Volume: 300 ml
Weight: 660g
Interface inner diameter: 6mm
Tower interface material: PTFE
Bottle material: Borosilicate glass

How to use JT-300 anti Back Suction Device:
Connect to vacuum pump negative pressure nozzle to prevent liquid from entering the pump, to prevent corrosion of the pump body due to the inlet liquid, prolong the service life of the vacuum pump, and cooperate with the filter (multiple filter, solvent filter).

Note:
1. Open the vacuum pump, without human observation and control. Once the liquid is filled into the trapped bottle, the trapping valve acts to prevent the liquid from intruding into the pump.
2. Turn off the power of the vacuum pump, remove the trap bottle, unscrew the blue cap, pour off the liquid in the trap, and install it again and again.

Other accessories: Manifolds Vacuum Holder     Solvent Filter

Download Brochure

SKU: gm-series Category: Tags: , ,

Manual

Please download Manual from here.

Catalog

Catalog