SP2100/SP2100PC Visible Spectrophotometer |
| SP-2100 is an intelligent visible spectrophotometer that has various functions as well as advanced instruments. The instrument contains features such as high automatization, various functions, strong plasticity, and so on. The Win-spec photometric software with diversified application functions is accompanied with the instrument as a present, which combining with special accessories for different purpose, the stick and the carrot, enables you to obtain a solution for sample analysis that fits to your individuation requirement. User can find a solution that well-designed for you from our company whichever industry you are engaged in. |
| | | | Basic testing mode: | | Basic measurement | Photometric measurement,(A/T) | | Concentration measurement (C ) | | Concentration measurement | Slope method (C=K*A) | | Standard curve method | | Software functions | Win-spec workstation, SP-2.33EN | | Photometric analysis | T, A, and C measurement | | Quantitative analysis | Standard curve measurement; | | Kinetic analysis | Measurement with time-scanning. | | Spectrum scan analysis | Spectrum scan function |
| | | | Main Specification: | | Display | 2*20 characters LCD with blacklight function | | Light Source | 6V10W Halogen Lamp(2000 hours) | | Sample Compartment(Max) | 100mm Optical Path | | Standard Cell Holder | 10mm | | Standard Cell Configuration | 10mm Glass cell(4pcs) | | Power Requirement | 110/220VAC,50/60Hz,±10% |
| | | | Basic instrument functions: | | 100%T or 0%T setup | Automatic. | | System self-testing | Wavelength self-testing, light soures self-testing,filter switching,energy calibrating. | | Signal output | RS-232C, Analog | | Communication function | Intercommunication can be realized after connecting to PC |
| | | | Performance&Specification | | Item | SP-2100 | SP-2100PC | | Optic system | Littrow type optic system with 1200 grooves/mm diffraction grating monochromator. | | Wavelength range(nm) | 325-1000 | | Spectrum bandwidth(nm) | 4 | | Wavelength accuracy(nm) | ±1 | | Wavelength repeatability(nm) | 0.5 | 0.3 | | Photometric range | 0-125%T,-0.097-3A | | Photometric accuracy | ±0.5%T | | Photometric repeatability | 0.3%T | | Stray light | ≤0.3%T (at 220nm) | | Stability | ±0.002A/hr(at 500nm,after warming up for 1hour ) | | Noise | ±0.001 | | Baseline flatness | ±0.004A | | Display | 128*64 digital LCD Displayer |
| | |
| Standard configuration | | 50mm manual four-cell holder, 1pcs | | 10*10*45 mm standard glass cuvettes, 4pcs | | RS-232C connection cord, 1pcs | | Power cable, 1pcs | | User manual, 1pcs | | Operation procedure, 1pcs | | Win-spec software SP-1.33EN, 1pcs | | | | | | Function configuration | | Standard type: SP-2000 | | The operation can be carried out by the instrument. It also can be controlled by PC, which is easy to master, and plenty of testing data can be stored, data processing such as calculation, statistic analysis and tab also can be realized. | | | | Note: There may not be special notifications when the technical specification,profile and configuration changed. Please, the products will be in agreement with the real models. |
|
: |
|
|