SP-2102UVP UV-Visible Spectrophotometer
|
* 6.4 inch high definition LCD with large screen. * Real-time multitasking kernel, whole graphic cross-talking interfaces. * Memory that without losable, optimized source configuration, last working status be remembered automatically. * Powerful function of self-testing and calibration: dark current calibrating,automatically finding the zero order light, characteristic spectral line with656.1nm of deuterium lamp positioning. * Fancy image and character output interface. * PC connecting for choice, and various versions of Win-scan software that professional version or enhanced version for choice. Resolving power of 2nm, which fits the requirement for drug codex of different nations. | | | | Recommended application areas: | Main performances reach the level of the same indexes that from imported instruments and domestic advanced instruments. It¡¯s an indispensable instrument for quality control that is widely used in pharmaceutical analysis, food, medicines and healthy, life sciences, biochemical analysis and organic chemistry. It's also an ideal testing tool in schools and scientific research academies. | | | | Specification: | | MODEL | SP-2102UVP | | Optic system | Littrow type optic system with 1200 grooves/mm diffraction grating monochromator. | | Light path | 100mm | | Spectrum band width | 2nm(1nm or 4nm selectable) | | Wavelength range | 190-1100nm | | Wavelength accuracy | ±1nm (automatic system calibration ) | | Wavelength repeatability | 0.5nm | | Stray light | ≤0.3%T (at 220nm & 340nm) | | Photometric mode | T, A, and C measurement; | | Photometric range | 0-125.0%T, -0.097-3.000A | | Photometric accuracy | ±0.3%T | | Photometric repeatability | 0.2%T | | Stability | ±0.002A/hr (at 500nm, after warming up for 1 hour) | | Baseline flatness | ±0.004A |
| | | | Main Specification: | | Display | 320X640 large screen graphic LCD | | Light Source | 6V 10W Halogen Lamp(2000 hours) | | Deuterium lamp(1000 hours) | | Sample Compartment | 100mm Optical Path | | Standard Cell Holder | 10mm | | Standard Cell Configuration | 10mm Glass cell(4pcs) | | Power Requirement | 110/220VAC |
| | | | Basic instrument functionsBasic instrument functions: | | Storage function | Dynamic storage function, optimized resource configuration, standard curve farthest storage,last working status automatically be remembered. | | 100%T or 0%T setup | Automatic | | System self-testing | Wavelength self-testing, light soures self-testing,filter switching,energy calibrating. | | Light source switching | The switching point can be set at any position at the wavelength range of 325-355nm to improve testing accuracy. | | Light source management | Light source on/off status can be controlled to elongate its working life. | | Signal output | RS-232C, LPT | | Communication function | Intercommunication can be realized after connecting to PC | | Print function | HP parallel printer of spray-ink or laser can be connected. |
| | | | Extended function (Accessories or workstation software should be chosen.) | | Automatic multi-cells holder | | Auto-sorting test, or manual-sorting, 4 cells and 6 cells for choice. | | Micro-volume testing | | 100ul, as the minimum volume. (Special cell holder and cuvette should be used.) | | Constant temperature testing | | Testing samples under the condition of constant temperature. | | Electronic constant temperature accessory or water cycling | | constant temperature accessory should be chosen. |
| | |
| Standard configuration: | 10mm manual four-cell holder, 1pcs 10×10×45 mm standard glass cuvettes, 4pcs 10×10×45 mm standard quartz cuvettes, 2pcs RS-232C connection cord, 1pcs Power cord, 1pcs User manual, 1pcs Operating protocol, 1pcs | | | | Main testing interface: | Upgraded SP-2102UVP UV-Vis spectrophotometer uses 6.4 inch graphic type LCD with large screen that substitutes previous simple display mode of character type in which new functions, such as spectral scanning, quantitative analysis, ect. are included. The sample’s absorbance, transmittance, or concentration is real-time recorded. The spectral scanning curve and standard curve can be drawn, and the testing parameters can be shown in list, for example, the wavelength, light source energy, on-off status of the light source, operating suggestions, and so on. The human design fits the operating custom of most users. SP-2102UVP UV-Vis spectrophotometer supplies diversified testing mode, mainly about: Photometric analysis: absorbance, transmittance, concentration measurement. Quantitative analysis: measurement with slope and intercept (C=K* Abs. + B), measurement with standard curve. Spectral scanning: whole wavelength range scanning, section of the wavelength range scanning, peak and valley identifying can be carried out. Main menu: The interface is clear and intuitionistic designed, and with function key suggests, user can easily enter into appointed interface. | | | | Accessories for choice: | Electronic constant temperature cells holder Water cycling constant temperature cells holder 5-100mm light path manual multi-cells holder Micro cell holder, with 1-4mm slit, single cell 100-200μl ultra-micro cell holder, single cell Optic film rack 8- 22mm test tube rack, single cell 10-100mm light path cell holder for cylindraceous sample, single cell 7- 25mm mirror reflection apparatus AC-230 type intelligent temperature/sample controller AC-220 type intelligent auto-sample controller AC-210 type intelligent temperature controller | | | | Quantitative analysis: | By inputting the standards' concentration and measuring eachabsorbance, user can easily establish a fitted curve of 10 standards. The system automatically numbers and lists each sample’s absorbance and concentration. User can pick up the figure of standard curve, linear equation, and correlative coefficient the system automatically calculated, and evaluate the curve’s linear fitting effect. The established standard curves can be stored, printed out or recalled from memory for measuring unknown samples. Moreover, user can directly input the fitted parameters, such as the slope, intercept, etc, to quickly establish standard curve without inputting the concentration values of standard samples. | | | | Note: There may not be special notifications when the technical specification,profile and configuration changed. Please, the products will be in agreement with the real models. |
|
: |
|
|