Microscope Telescope Oven & Incubator Pipette Spectrophotometer    Visible Spectrophotometer    UV Spectrophotometer    UV-visible Spectrophotometer    Fluorescent Spectrophotometer    Double Beam Series Photometer & Colorimeter Cell Hand Held Refractometer Viscometer Polarimeter Abbe Refractometer Centrifuge Melting point machine Laboratory Balance Distillation Apparatus Ordinary autoclave Mixer, Stirrer & Shaker PH & Conductivity Meter Glassware & Lab Porcelain Plastic Consumables Hemoglobinometer Counter Water Bath Medical Refrigerator


image
Spectrophotometer arrow UV-visible Spectrophotometer arrow SP 2000UV

SP 2000UV Visible Spectrophotometer

SP 2000UV Visible Spectrophotometer

SP 2000UV Visible Spectrophotometer They have a large sample compartment that will accept from 5 mm to 100 mm path length rectangular cuvettes and various accessories. 2-line, 20-character LCD readout displays absorbance, transmittance, concentration and wavelength and gives easily understood instructions. The built-in RS-232 serial interface enables the instruments to be connected to a computer or printer. A friendly %T/A/C application software for Windows 98 is enclosed and allows inexperienced user to operate the instruments.

- Excellent optical performance, low stray light enables highly precise measurement in a wide photometric range.

- A full complement of sampling accessories such as cell holders, COD test tubes holder, Adjustable holder for cells up to 50mm flow cells, temperature controllers and software packages such as Kinetic and Standard Curve are available to optimize the SP2100 series for specific applications.

- Creates and saves a standard curve with up to 8 standards. Calculates concentration of unknowns and saves factors. Calculates absorbance ratio and Absorbance difference. (require a SPEC-PC Application Software)

Specifications:

Model
SP-2000UV
Display
2 line, 20 character LCD
Spectral slitwidth(nm)
5nm
Optical system(nm)
Littrow type, single beam, grating system 1200 line/mm
Wavelength range(nm)
200-1000
Wavelength accuracy(nm)
± 2 nm
Wavelength repeatability
± 1 nm
Wavelength selection
Auto
Stray light
≤0.3%T@ 220nm & 340nm
Photometric range
0-125.0%T, 0-2.5A, 0-1999C(0-1999F)
Photometric accuracy
± 0 .008@0.5A
Drift
≤0.002A/hour after warm up
Light source
Tungsten halogen lamp, Deuterium
Auto zero
Yes
Detector
Silicon photodiode
Data output
Analog output, RS-232C Series I/O port
Standard sample holder
4-position, 10*10 mm rectangular cell
: