WDZX-120KC/WDZX-200KC/WDZX-300KC Horizontal Pressure Steam Sterilizer
Intelligent microcomputer control system:
Using LED digital control system, After sterilization finished, sterilizer will automatic alarm and shutdown.
Interlock device:
The control system can real-time supervision the sterilizer chamber’s temperature and pressure. Only under the safety temperature and pressure can open the sterilizer’s cover. Make sure the operator’s safety.
The structure of cover’s opening:
Using 8 rotary extendable stick to improve sealing and safety performance.
Preset program:
Can preset fixed program that sterilize solid body.
Memory storage system:
Store the last operation program so convenient next operation.
Exhaust steam control:
After sterilization, exhaust steam valve should be opened ( Digital display screen reminds exhaust steam) when sterilization time run out.
Interface check:
provide temperature and pressure check interface: convenient to check multiple positions temperature measurement.
Digital display screen:
Digital display screen and working indicator light display running state.
Safety Devices:
Interlock device, overtemperature, and overpressure protecting system, burned protection, safety relief valve, current leakage protector and automatic fault detection.
Print function:
Print the current temperature and sterilization time.
Technical Parameter
Parameter/Model | WDZX-120KC (120L) | WDZX-200KC (200L) | WDZX-300KC (300L) |
Configuration | Semi-automatic control | Semi-automatic control | Semi-automatic control |
The main material | Stainless steel | Stainless steel | Stainless steel |
Volume/GW | 120L/225Kg | 200L/300Kg | 300L/333Kg |
Voltage/Power | 380V/2.5Kw X3 | 380V/3.0Kw X3 | 380V/4.0Kw X3 |
Packing Size (L X W X H mm) | 1340x730x1700 | 1640x830x1800 | 1640x930x1900 |
Product size (L X W X H mm) | 1220 x 620 x 1540 | 1550 x 720 x 1640 | 1550 x 820 x 1740 |
Sterilization chamber volume (D X Hmm) | 400 x 960 | 500 x 1120 | 600 x 1240 |
Basket size(Upper length x upper width x lower length x lower width x height mm) | 380 x 340 x 380 x 225 x 140 | 480 x 440 x 480 x 250 x 195 | 500 x 540 x 500 x 300 x 230 |
Time setting range | 0-99 h | 0-99 h | 0-99 h |
Rated working pressure | 0.217MPa | 0.217MPa | 0.217MPa |
Sterilization temperature setting range | 50~134℃ | 50~134℃ | 50~134℃ |
Scope of application
This type of product meets the national provisions of pressure vessel design standard. Our factory has obtained the necessary license of sterilized products and certificate of State Food and Drug Administration. This horizontal pressure steam sterilizer is a new type of product from our factory. The product has the safety of structural design, and a simple mode of operation, and all necessary control functions. The sterilizer is equipped with interlocking device. The cover is locked when it has pressure in the chamber. No heating after operating mistake. The main part of the sterilizer is made of stainless steel. The product meets the national standard for medical operations, It is an ideal product to sterilizing instrument, dressing medicine, glassware, culture medium at the medical health care, universities and colleges, biological research, food and chemical industry.
Sterilization Principle
Pressure Steam Sterilizer is designed for the used of heat to kill microorganisms principle. Sterilization principle is to use the principle of gravity displacement of the steam from the top down in the sterilizer, the cool air is discharge from the vent, replaced by cold air discharge saturated steam, the use of the latent heat released by steam sterilization to achieve the article. The advantage of using steam, heat sterilization method that has strong bactericidal effect, which can increase the water content of bacterial protein, making it easy to solidification due to heat, the acceleration process dead microorganisms.
Product Standard
Q31/0114000133C003-2015 “Horizontal Pressure Steam Sterilizer”
Features
1 Rotary structure of fast openings | 8. Sterilization temperature setting range (50°C-134°C) |
2.Automatic control of the sterilization cycle program | 9. Double scale numerical indication pressure gauge |
3.Interactive safety interlock device | 10. Self inflating type seal |
4.Water supply cut protecting equipment | 11.Sterlization end automatic alarm |
5. Digital window display working status | 12. Printer (option) |
6.Time setting range (0-99Hours) | 13. Inner loop exhaust system |
7The work pressure is 0.217Mpa | 14. Touch operation. |
Technical parameters
Configuration | Semi-automatic control | Volume? GW | 120L/230Kg |
Power | 380V/7.5Kw | The main material Thickness (mm) | stainless steel/3.0 |
Sterilization | Φ400×960 | Packing size (mm) | 1160x622x1550 |
Main parts
NO. | NAME | QTY | NO. | NAME | QTY |
1 | Door interlock switch | 1 | 2 | Switch/DC24V≤500mA | 1 |
3 | Solid-state relay/440V 40A | 1 | 4 | Heater/2.5Kw | 3 |
5 | safety valve | 1 | 6 | Relief valve | 1 |
7 | Pressure gauge | 1 | 8 | Seal ring | 1 |
9 | Computer board | 1 | 10 | Power fuse?RT-18 AC380V | 3 |
11 | Temperature sensor/PT100 | 1 | 12 | Fuse/AC250V 2A | 1 |