Shop

Vacuum Blood Tube

SKU: vacuum-blood-tube Category: Tag:

Vacuum Blood Tube

No additive Tube

Specification:
        Color Code: Red
        Specifications: Ø13X75mm, Ø13X100mm
        General Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
        Maximum Centrifugal Rotation Speed: 5000 turns/min.
        Blood Cloting Time: ≤2.5h
        Operation Temperature: 0 ℃-37 ℃
        Maximum Vacuum Tolerance: ±10%
Attentions:
Do please drain the vacuum in the tube when the sampling dosage is below the tube design dosage.
No additive Tube
Description:
The no additive tubes are applicable to the immunochemistry, immunology, serumology and all kinds of virus tests as well as the blood sampling and storage in blood collection stations. The tube walls are specially processed for preventing the sticking and hemolysis, which not only blood sampling tubes but the test tubes.

PT Tube

Specification:
        Color Code: Blue
        Specifications: Ø13X75mm
        General Sampling Dosage: 1.8ml, 2.7ml
        Type of Additive: 3.28% sodium citrate
        Operation Temperature: 0 ℃-37 ℃
        Maximum Vacuum Tolerance: ±5%
Attentions:
During the operation, care for the followings:
1. Soon after blood sampling.mixing it 5-6 times by turning the tube 180°.
2. Sampling the dosage as required to ensure the test accuracy.
3. This tube is suitable fixed to the double direction flexible needles.
Description:
PT tubes are applicable to the checks for blood coagulation. The vacuum tubes are designed according to the 1:9 proportions of anti-coagulants and blood samples. It can ensure an accurate blood dosage and anti-coagulants quantity as well as the high precision. Because the low toxicity of the sodium citrate, it can also be used to the blood storage.

ESR Tube

Specification:
        Golor Gode: Black
        Specifications: Ø13X75mm
        General Sampling Dosage: 1.6ml, 2.4ml
        Type of Additive: 3.8% sodium citrate
        Maximum Vacuum Tolerance: ≤5%
Attentions:
During the operation, do pay attentions to the followings:
1. As soon as the sampling, upside down the tube by 180°shaking and fixing fully.
2. Sampling the blood dosage as required to ensuring the test accuracy.
Description:
The tubes are specially used for determination of the erythrocyte sedimentation rate (ESR) by the Westergren’s Method. The mixing ratio is 1 part citrate solution to 4 parts blood. ESR measurements refer to the Westergren method.

Heparin Tube

Specification:
        Color Code: Green
        Specifications: Ø13X75mm, Ø13Xl00mm
        General Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
        Types of Additives: Sodium Heparin, lithium Heparin
        Maximum Centrifuge Speed: 5000 turns/min.
        Maximum Vacuum Tolerance: ±10%
Attentions:
During the Operation, do please care for the followings:
1. Soon after the sampling, turn the tube 180° upside down,shaking and mixing 5-6 times.
2. Sampie the dosage as required in order to avoiding the inabiIity of the determination of the calcium due to the relative higher content of the heparin.
3. Heparin Anti-coagulation Blood sample should be used within 6 hours after sampling, otherwise, the blood will coagulate again.
Description:
The heparin tubes are use to blood sampling in clinical biochestry, emergency care biochemical and hemorrheological tests.

EDTA Tube

Specification:
        Color Code: Purple
  Specifications: Ø13x75mm
  General Sampling Dosage: 2ml, 3ml, 4ml, 5ml
  Types of additives: EDTAK2, EDTAK3, EDTANa2
  Operation Temperature: 0 ℃-37 ℃
  Maximum Vacuum Tolerance: ±10%
Attentions:
1. Soon after the sampling, turn the tube upside down by 180°, shaking and mixing 5-6 times.
2. Sampling the enough dosage as required to ensuring the accurate of the test result.
Description:
The tubes are applicable to the clinical blood test and suitable for the blood cells analysis. The internal walls of the tubes are coated with the anti-sticking agent, and meanwhile add the anti-coagulant. EDTA anti-coagulant has low effects on the blood cell integration and blood cells configuration, which can restrain the platelets integration.

Oxalate Tube

Specification:
Color Code: Gray
  Specifications: Ø13 X75mm,Ø13 X100mm
  Normal Sampling Dosage: 2ml, 3ml, 4ml, 5ml
  Types of the Additives: Sodium Fluoride + Potassium Oxalate  Sodium Fluoried + Sodium Heparin
  Maximum Centrifugal Rotating Speed: 5000 turns/min.
  Maximum Vacuum Tolerance: ≤5%
Attentions:
Because the Sodium Fluoride has a good effect of preventing the blood sugar from degradation, turning the tube 180°, upside down, shaking and mixing 5-6 times slowly..
Description:
The tubes are applicable to the blood samples test on the aspects of blood sugarsugar tolerance, red blood cell electrophoresis, Alkali-Resistant HB Determination, and sugar dissolution. Due to the add of the inhibitor and special process of the internal tube walls, it can maintain the blood original characters for a long time, and the metabolism of the RBC relative ceased.

Pro-Coagulation Tube

Specification:
Color Code: Nacarat
  Specifications: Ø13X75mm, Ø13X100mm
  Normal Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
  Coagulation Time: 10-30 Minutes
  Maximum Centrifugal Speed: 5000 turns/min.
  Operation Temperature: 0 ℃-37 ℃
  Maximum Vacuum Tolerance: ±10%
  Cloting Time: When the platelets are normal, the coagulation time is not more than 5 minutes.
Attentions:
1. Soon after the sampling, turn the tube 180° upside down, shaking and mixing for 5-6 times. Only can centrifuge the sample till the blood coagulated completely.
2. When the sampling dosage are not more than the required dosage, please drain the vacuum in the tubes.
Description:
The tubes are use to the blood sampling for biochemical, immunization test. The internal walls are coated with the anti-wall sticking agent and meanwhile add the pro-coagulant, which has the characters of temperature flexible, fast coagulation, fibrin never recur.

Gel and Clot Activator Tube

Specification:
Color Code: Yellow
  Specifications: Ø13X75mm, Ø13X100mm
  Normal Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml
  Complete Coagulation Time: 10-30 Minutes
  Maximum Centrifugal Speed: 5000 turns/min.
  Operation Temperature: 0 ℃-37 ℃
  Maximum Vacuum Tolerance: ±10%
Attentions:
1. Soon after the blood sampling, turn the tube 180° upside down, shaking and mixing 5-6 times.
2. In order to help the gel to form a barrier, only can centrifuge the blood 8-10 minutes till the blood coagulated completely..
Description:
The tubes are applicable to blood serum biochemical test, immunization test, and drug test etc.the internal walls are Coated with pro-coagulant which and shorten the coagulation time significantly. Using the imported separation gel to prevent the protein in serum from adhesion and maintain a stable status. The centrifuged separation gel is solidified and forming a barrier to separate the serum from blood red cells and stop the exchange of the substances between them. Thus obtain the high quality serum.

ESR Tube

Specification:
Color Code: Black
  Type of Anti-coagulant and Content: 3.8% sodium citrate
  Status of the Anti-coagulant: liquid
  General Tube Specifications: 9X120mm
  Rated Sampling Dosage: 1.28ml
  Mixing ratio: 1 part citrate to 4 parts blood
  The Proportions between the Anti-coagulant and volume of blood sample
  Vacuum Tolerance: ≤5%
Description:
The tubes are specially used for blood sampling for determination of the erythrocyte sedimentation rate (ESR) by the Westergren Method.

Vacuum Blood Tube Products’Characters

Products’ Characters

1. All the vacuum tubes’are produced in the clarification plants and their wall are cleaned by ultrasonic waves and washed by the deionized water, sterilized by cobalt 60 radiation, while the inner wall are siliconized, produced in clean room which prevent the foreign particles coming into the products effectively.

2. The tubes adopt the double covers design and are well sealed by the medical-purpose butyl disks which ensure a stable vacuum in the product’s validation period. The internal sides of the tubes are coated with the lubricant, and outside are sleeved with plastic safety caps which make the opening and shutting much easier. The sideways opening style can prevent the blood splashing and pollutions.

3. The tubes adopt the international general colored caps, which is easy for identification, selection and classification, and can prevent the mixing and mistakes occurring during the operations.

4. Use the PET tubes are produced according to the international norms with good compatibilities and suitabIe of varied chemical and biological analysis, immunochemistry, and blood testing. The materials are of Iightness and firm that can bear 5000g centrifugal acceleration and has the characters of easy for transportation and processing which make the immediate direct high pressure sterilization after use or destroying possible without any poisonous gas emitting and environmental friendly.

5. Using the US produced coating equipments and technologies, which make the additives evenly coated on the walls for avoiding the mis-inspection and re-inspection.

6. The vacuum room can maintain the status 24 months to ensure the accurate blood sampling dosage. Different kinds of vacuum level tubes are for your choices according to the temperature and sea levels.

7. According to the requirements of the customers, we can supply the double labels tubes and strip code tubes to ensure the patients test accurate and convenient for the renew of the hospital management system.

Description:
In recent years, due to the rapid development of clinical testing methods and progress on the automatic analytical instruments, the customers make more requirements on the blood sample collection system not only safety but also accurate, easy for operation, products quality and can preserve the sample’s original characters, the blood storage time.

Inducing the wholes sets of vacuum blood tube producing lines, We are advocating to the R&D and manufacturing vacuum blood tube on the shoulder of the mature blood collection technologies from abroad. We have innovated the methods and used the special accurate instruments to control the critical aspects affecting product’s quality, such as the process of tube wall, vacuum tightness, loadability of separation gel and dosages. Our vacuum blood tubes are safer, simpler, more accurate and more economical which can meet different requirements of the medical care persons and research and development personnel.

Download Brochure Page 1
Download Brochure Page 2
Download Brochure Page 3