S23A VISIBLE SPECTROPHOTOMETER (Tube & Cuvette) | | | | |   | | | | | S23A is special for Environmental Protection Department and Education Department, Can use testing tubes or cuvette to make measure directly. | | | | Features: | | * Using universal φ12+0.4*100 mm testing tubes or cuvette to make measure directly. | | * Whole aluminum metal alloy die-castings. | | * Pre-aligned halogen-tungsten lamp,offer ease of use and simple maintenance. | | * Built in SCM technology,auto 0%,auto 100%,error-free T/A transformation. | * Transmittance test, absorbance test, concentration factor setting and concentration direct readout functions. | | * Analysis with data processing software. | | | | | How to select the test tube Generally the round test tube is not for optic purpose unless it is pre-checked strictly. 1. Check size. (The size should be φ12+0.4*100 mm) 2. Check the surface of tube. (It should be no bubbles, no scabs, no thread like things.) 3. Warming instrument and set the wavelength at 360 nm. 4. Pour some pure water into tube and insert it to the test tube well in sample apartment. Then put some mark on the tube opposite the white mark at the instrument. 5. Put the other test tube into instrument one by one and get the readout for everyone and put mark at everyone. We can divide them in many groups. In each group the differential of readout for every tub is less then ±0.02A. 6. We can use tubes in same group for blank, sample, and standard solution needn’t check the tube every time. | | | | Specifications: |
| Wavelength Range | 340~950nm | | Wavelength Accuracy | ±2.5nm | | Wavelength Repeatability | <1nm | | Photometric Range | 0.0-199.9%T | | -0.3-2.999A | | 1~9999F | | 0~9999C | | Photometric Accuracy | ±2%(τ)(Tube) ±0.5%(τ)(Cuvette) | | Photometric Reproducibility | 0.3%(τ) | | Stray Light | ≤0.5%(τ) | | Spectral Bandwidth | 12nm | | Display Mode | 4digit(LED) | | Lamp | Halogen-Tungsten Lamp | | Optical System | C-T configuration diffraction grating monochromator | | Interface | RS232 Serial Port | | Dimension | 370*320*210 | | Weight | 6.5KG |
| Standard Configuration: | | | | S23A Spectrophotometer | 1 Set | | | 1 CM Glass Cuvette | 1 Pairs | | | Cuvette Rack | 1 PC | | | Power Cable | 1 PC | | | User Manual | 1 PC | | | Fuse (2A) | 1 PC | | | Packing List | 1 PC | | | | | | | | | | | Optional Accessories | | | | Fuse (2A/3A) | | | | Pre-aligned halogen-tungsten lamp | | | Glass Cuvette 1 cm | | | | Cuvette Rack | | | | Praseodyminum-Neodymium Optical Filter | | | Mini Printer | | | | Printer Cable | | | | Spectrophotometer data processing software package | | Comunication Cabel | | |
S22/S22PC Visible Spectrophotometer | | |  |  | | |
| * Whole aluminum metal alloy die-castings. | | * Pre-aligned halogen-tungsten lamp,offer ease of use and simple maintenance. | | * Built in SCM technology,auto 0%,auto 100%,error-free T/A transformation. | | * Transmittance test, absorbance test, concentration factor setting and concentration direct readout functions. | | * Analysis with data processing software. | | * Spacious sample compartment, 4 position cuvette rack, adaptable for 1-5cm optical path rectangular cuvettes. |
|
| Wavelength Range: | 340-1000nm | | Wavelength Accuracy: | ± 2nm | | Wavelength Reproducibility: | =1nm | | Spectral Bandwidth: | 6nm | | Photometric Accuracy: | ± 0.5%(t) | | Photometric Reproducibility: | ± 0.3%(t) | | Stray Light: | <0.5%(t) | | <0.2%(t) (S22PC) | | Scale: | TRANS: 0-199.9% | | ABS: -0.3-2.999 | | FACT: 1-9999 | | CONC: 0-9999 | | Display Mode | 4digit(LED) | | Lamp | Halogen-Tungsten Lamp | | Optical System | C-T configuration diffraction grating monochromator | | Interface | RS232 Serial Port, Parallel port | | Dimension | 370*320*210 | | Weight | 7KG |
|
| | | Standard Configuration: | | S22PC or S22 1 PC | | Power cable 1 PC | | Operation Manual 1 pc | | Fuses (2 A) 2 pcs | | 1 cm glass cuvettes 2 Pairs | | 1cm 4 position cuvette rack 1 PC | | Packing list 1 PC |
| | | | Optional Accessories and Spare Parts: | | 1. Fuse(2A/3A) | | 2. pre-aligned UV-VIS combine lamp | | 3. Glass cuvette 1cm, 2cm, 3cm, 5cm | | 4. 5 cm cuvette rack (adaptable for 1-5 cm Cuvette) | | 5. Qualitative-quantitative data processing software packag | | 6. Comunication Cable | | 7. Mini Printer | | 8 Printer Cable | | 9. Praseodymium-Neodymium Optical Filter |
| | |
752S UV-VIS SPECTROPHOTOMETER | | | | | Display Model: 4 digital LED | | Lamp: Patent assembled Hamamatsu L2D2 long life Deuterium Lamp and RoYal long life | | Halogen-Tungsten Lamp | | Optical system: C-T configuration diffraction grating monochromator | | Interface:RS232 serial port | | Dimensions: 370/320/240 mm | | Weight: 10Kg | | | | Features: | | * Whole aluminum metal alloy die-castings. | | * Patent assembled pre-aligned deuterium and halogen-tungsten lamp,long life and simple maintenance. | | * Advanced optical system ensures low stray light. | | * Built in SCM technology,auto 0%,auto 100%,error-free T/A transformation. | | * Transmittance test, absorbance test, concentration factor setting or concentration direct readout functions. | | * Analysis with data processing software. | | * Spacious sample compartment, 4 position cuvette rack, adaptable for 1-5cm optical path rectangular cuvettes. | | | | Specifications: | | Wavelength Range: | 200-960 nm | | Wavelength Accuracy: | 2nm | | Wavelength Reproducibility: | <1nm | | Spectral band width: | 2nm | | Photometric Accuracy: | 0.5%(t) | | Photometric Reproducibility: | 0.3%(t) | | Stray Light: | <0.5%(t) (360nm, NaNO2) (220nm, NaI) | | Photometric range: | TRANS: 0-199.9% | | ABS: -0.3-2.999 | | FACT: 1-9999 | | CONC: 0-9999 |
| | | | Standard Configuration: | | 1) 752S spectrophotometer 1 set | | 2) Power cable 1 pc | | 3) User Manual 1 pc | | 4) Certificate of quality checking 1 pc | | 5) Fuses (2A) 2 pcs | | 6) 1cm glass cuvette 2 pairs | | 7) 1cm quartz cuvette 1 pair | | 8) 1cm 4 position cuvette rack 1 pc | | 9) Packing list 1 pc |
| | | | Optional Accessories: | | 1) Fuse (2A/3A) | | 2) Assembled pre-aligned deuterium and halogen-tungsten lamp | | 3) Glass cuvette 1 cm, 2 cm, 3 cm, 5cm | | 4) Quartz cuvette 1cm, 2cm, 3cm, 5cm | | 5) 5 cm cuvette rack £¨adaptable for 1-5cm cuvette | | 6) Praseodymium-Neodymium optical filter | | 7) Holmium oxide optical filter | | 8) Mini printer | | 9) Printer cable | | 10) Data processing software package | | 11) Comunication cable |
|
7 Series Spectrophotometer | | | 721(Visible) | 722(Visible) | | | | | | 723/723PC(Visible) | 750 (UV) | | | | | | 752 (UV-Visible) | 754/756 (UV-Visible) | | | |
7 Series UV-Visible Spectrophotometer adopts microprocessor control technology, can meet the requirements of qualitative and quantitative tests for most samples in conventional laboratories. The instrument is widely used in medical and health, clinical examination, biochemical, chemical engineering, environmental protection, food industry, academy and quality control departments, etc. The instrument with a low price and high performance is your best choice. | | | 1. The instrument adopts LCD display and a sample compartment for 0.5~10 cm cells. | 2. Keyboard operation is simple & clear, "the key of spectroscopic " can use easy adjust 0% & 100% automatically, and there is the function of automatic 0%(T), 100%T adjustment and no error T-A transform. Factor can be set, the display result may be consistence. RS232 port is equipped. | 3. The automatic switch apparatus of light source is equipped with high precision auto-scan structure in UV Spectrophotometer. | 4. Excellent technics and strict components selection make the instrument have outstanding measure repeatability and stability. | | 5. Patent be gained Streamline form, the popular paint which is resist to the chemistry, suitable to the modern laboratory environment. | | | | | | Specification: |
Model | 754/756 (UV-Visible) | 752 (UV-Visible) | 750 (UV) | 723/723PC (Visible) | 722 (Visible) | 721 (Visible) | Wavelength Range (nm) | 200~1000 | 195~1020 | 200~400 | 325~1000 | 325~1020 | 360~1000 | Transmission Ratio Range (%T) | 0.0~125.0 | 0.0~199.9 | 0.0~199.9 | 0.0~125.0 | 0.0~199.9 | 0.0~199.9 | Absorbency Range (A) | -0.097~2.5 | -0.301~1.999 | -0.301~1.999 | -0.097~2.5 | -0.301~1.999 | -0.301~1.999 | Consistence Display Range | 0~1999 | 0~1999 | 0~1999 | 0~1999 | 0~1999 | 0~1999 | Wavelength Accuracy (nm) | +/-1 | +/-2 | +/-2 | +/-1 | +/-2 | +/-3 | Spectrum Bandwidth (nm) | 4 | 4 | 2 | 4 | 4 | 5 | Measure precision (%T) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 1 | Stray Light (%T) | <=0.3(@220nm) | <=0.3(@360nm) | <=1 | scan software | NO /YES | NO | NO | NO /YES | NO | NO | Power Supply Voltage (V) | 110V or 220V +/- 10% 50~60HZ | Output Port | RS232 | Dimensions (mm) | 460*360*200 | Package | 550*440*280 | Gross Weight/Net Weight (kg) | 12/10 | 12/10 | 12/10 | 12/10 | 10/8 | 10/8 | Standard Configure | 1 CM Glass Cell 1 Set | 1 CM Glass Cell 1 Set | 1 CM Quartz Cell 1 Set | Optional | 5~10cm Sample Holder |
|
|
|
|