laboratory
Sunday, 05 February 2012
top left pic
top pic
equipment
 
laboratory
Home
logo right
Products
Microscope Spectrophotometer Oven & Incubator PH & Conductivity Meter Titrator, Ion Meter & D.O.ANALYZER Pipette Centrifuge Photometer, Colorimeter & others Viscometer Polarimeter Abbe Refractometer Hand Held Refractometer Melting point machine Balance Distillation Apparatus Autoclave & Sterilizer Mixer, Stirrer & Shaker Vacuum Blood Tube Hemoglobinometer, Hemocytometer & Colonometer Water Bath,Oil &Dry Bath Muffle Furnace Sample Concentration Flame Photometer Biological Safety Cabinet Laminar Flow Cabinet Cell (Cuvette) Gas Chromatograph Diaphragm Vacuum Pump

Catalog and Manual

Catalog

Download E-catalog

Require Original Catalog

Require E-manual


image
Flame Photometer

FP6410  Flame Photometer

 
Specifications:
A lot of new technology and new materials are adopted. Such features as LCD display, menu-type instruction operation, curve storage, flameout protector and outside printout are enabled by the application of top grade embedded mono-chip computer circuit.
FP-6410
Specification: 
Range K: 0~999.9
Na: 0~999.9
Li: 0~999.9(Optional)
Sensitivity K: 0.2ug/mL
Na: 0.2ug/mL
Linearity K: 0.2ug/mL
Na: 0.7ug/mL
Drift less than 3% within 15s
Reproducibility 3%
Aspiration rate <6mL/min
Fuel supply L.P.G.
 
Working conditions:
1
Envirmental temperture: 10 Deg.C~35 Deg.C
2
Relative humidity: <85%
3
The instrument should be placed horizontally, avoiding direct sunshine radiation. There is no disturbance of strong electromagnetic field or vibration.
4
Fire extinguishing device should be equipped in the application field and good aeration should be guarznteed. Power supply: 220V +/- 22V, frequency 50Hz +/- 1 Hz, with good grounding.
 
FP6410
Standard Configuration:
1
Main Instrument 1 PC
2
Power Cable 1 PC
3
Chimney 1 PC
4
Clearing rod 2 PC
5
Air compressor 1 PC
6
Printer SP-T 2425SK 1PC
  
 
Optional accessories
1
Printer SP-T 2425SK
2
Air compressor
3
Lithium filter
Download E-Manual: http://localhost/hinotek/dmdocuments/manual/flame-photometer/Hinotek-FP6410-Flamephotometer-manual.pdf
 
  
  
  

FP-640 Flame Photometer

Characteristics
* FP-640 flame photometer is an improved instrument based on the original model. 
* A digital display to show clear measurement results. Improved gas path system suitable for various fuels, easy to operate and with stable readings. 
* It meets the requirements of medical clinical test. In addition to new added functions of testing high contented K and Na, it has the detection function of Li salt taken by the mental patients.
* Complete set including a main instrument, an air compressor, accessories and spare parts
FP-640
Specifications:
Range K:0ï½ΕΎ199
Na:0~199
Li:0~199 (Optional)
Sensitivity K:0.2μg/mL
Na:0.2μg/mL
Linearity K:0.2μg/mL
Na:0.7μg/mL
Drift less than 3% within 15s
Reproducibility 3%
Aspiration rate <6mL/min
Fuel supply Gasoline or L.P.G.
 
FP640
Standard Configuration:
1. Main Instrument 1PC
2. Power Cable 1PC
3. Air compressor 1PC
4. Glass Jar 2PC
5. Petrol gasify cylinder 1PC
 
 
Optional Accessories
1. Air compressor
2. Lithium Filter
 Download E-Manual: http://localhost/hinotek/dmdocuments/manual/flame-photometer/Hinotek-FP640-Flamephotometer-manual.pdf
 
 
 
 
pic
email to us