PXSJ-216 Ion Analyzer | | | | | | Characteristic: | | 1. | Dot-matrix LCD. | | 2. | 2. Measure mV value,pH value, PX value | | 3. | Suitable for measuring solution concentration by way of concentration immediate reading,known adding method,sample adding and GRAN method. | | 4. | Measurement results can be stored,deleted, consulted and printed.It can store at most 50sets of measurement data.The user has two ways to select immediate printing or storage printing. | | 5. | With four slope calibration methods,including one point calibration,two-point calibration,multi-point calibration and multi adding calibration. | | 6. | Electricity cutting off protection.The stored data and parameters will be kept even if unusual electricity cutting off happens; | | 7. | With RS-232 interface,TP-16 printer can be connected. | | | | | | | Specification: | | 1. | Measurement range: | | | PX±1 or pX±2: 0.000-13.999 pX±1 or pX±2 | | | mV:-1800.0-1800.0mV | | | Temperature: -5-105.0℃ | | 2. | Resolution: | | | PX±1 or pX±2: ±0.001pX | | | mV:0.1mV | | | Temperature: 0.1℃ | | 3. | Accuracy of the electric unit: | | | PX±1 or pX±2: ±0.005pX ± 1 bit | | | MV: ±0.03%(FS) ±1 bit | | | Temp: ±0.3℃ ± 1 bit | | 4. | Stability of the electric unit: ±0.005pX ± 1 bit/3h | | 5. | Repeatability: 0.01pX | | 6. | Temperature compensantion:0-60.0℃ |
| | | | | PXSJ-226 Ion Analyzer | | | | | | Characteristic: | | 1. | Novel touching LCD screen | | 2. | With multi-points calibration(max/mum five points calibration) function, can set buffer solutions groups by yourself. | | 3. | With major ion mode, such as: H+, Ag+, Na+, K+, Cl‐, F‐, etc. | | 4. | Auto identification function of standard buffer solution. | | 5. | Measurement concentration unit can be switched among(0.000~19990)mg/L、 mol/L、 PX. | | 6. | Set self-defining ion mode, and can also measure the Other ion. | | 7. | With RS-232 interface,TP-16 printer can be connected and measuring result can be printed. Or communication with computer. | | 8. | Measuring potential,px(or PH),concentration and temp.value | | | | | | | Specification: | | 1. | Measurement range: | | | mV:-1999.99~1999.99mV | | | pH/pX:0.000~14.000pH/pX | | | Temperature:-5~105.0℃ | | | Concentration: various concentration value | | | correspondence to potential measurement range and | | | Indicator electrode | | 2. | Resolution: | | | pH/Px:0.01/0.001pX | | | mV:0.1/0.01mV | | | Temperature:0.1℃ | | 3. | Accuracy of the electric unit: | | | pX±1: ± 0.002pX ± 1 bit | | | pX±2: ± 0.005pX ± 1 bit | | | mV: ± 0.03%(FS) ± 1 bit | | | Temp: ± 0.2℃ ±1 bit | | | Concentration:± 0.5%(FS) ± 1 bit |
| | | | | | |
|
: |
|
|