FP6410 Flame Photometer |
| |
| Specifications: |
| A lot of new technology and new materials are adopted. Such features as LCD display, menu-type instruction operation, curve storage, flameout protector and outside printout are enabled by the application of top grade embedded mono-chip computer circuit. |
|
| Specification: | |
| Range | K: 0~999.9 | | Na: 0~999.9 | | Li: 0~999.9(Optional) | | Sensitivity | K: 0.2ug/mL | | Na: 0.2ug/mL | | Linearity | K: 0.2ug/mL | | Na: 0.7ug/mL | | Drift | less than 3% within 15s | | Reproducibility | 3% | | Aspiration rate | <6mL/min | | Fuel supply | L.P.G. |
|
| |
| Working conditions: |
1 | Envirmental temperture: 10 Deg.C~35 Deg.C | 2 | Relative humidity: <85% | 3 | The instrument should be placed horizontally, avoiding direct sunshine radiation. There is no disturbance of strong electromagnetic field or vibration. | 4 | Fire extinguishing device should be equipped in the application field and good aeration should be guarznteed. Power supply: 220V +/- 22V, frequency 50Hz +/- 1 Hz, with good grounding. |
|
| |
| FP6410 | | Standard Configuration: | 1 | Main Instrument 1 PC | 2 | Power Cable 1 PC | 3 | Chimney 1 PC | 4 | Clearing rod 2 PC | 5 | Air compressor 1 PC | 6 | Printer SP-T 2425SK 1PC | | | | | | | Optional accessories | 1 | Printer SP-T 2425SK | 2 | Air compressor | 3 | Lithium filter |
|
| Download E-Manual: http://www.hinotek.com/dmdocuments/manual/flame-photometer/Hinotek-FP6410-Flamephotometer-manual.pdf |
| |
| | |
| | |
| | |
FP-640 Flame Photometer |
| Characteristics | | * FP-640 flame photometer is an improved instrument based on the original model. | | * A digital display to show clear measurement results. Improved gas path system suitable for various fuels, easy to operate and with stable readings. | | * It meets the requirements of medical clinical test. In addition to new added functions of testing high contented K and Na, it has the detection function of Li salt taken by the mental patients. | | * Complete set including a main instrument, an air compressor, accessories and spare parts |
|
|
| Specifications: |
| Range | K:0~199 | | Na:0~199 | | Li:0~199 (Optional) | | Sensitivity | K:0.2μg/mL | | Na:0.2μg/mL | | Linearity | K:0.2μg/mL | | Na:0.7μg/mL | | Drift | less than 3% within 15s | | Reproducibility | 3% | | Aspiration rate | <6mL/min | | Fuel supply | Gasoline or L.P.G. |
|
| |
| FP640 | | Standard Configuration: | | 1. Main Instrument 1PC | | 2. Power Cable 1PC | | 3. Air compressor 1PC | | 4. Glass Jar 2PC | | 5. Petrol gasify cylinder 1PC | | | | | | Optional Accessories | | 1. Air compressor | | 2. Lithium Filter |
|
| Download E-Manual: http://www.hinotek.com/dmdocuments/manual/flame-photometer/Hinotek-FP640-Flamephotometer-manual.pdf |
| |
| |
| |