Microscope Oven & Incubator Pipette Spectrophotometer Photometer & Colorimeter Cell (Cuvette) Hand Held Refractometer Viscometer Polarimeter Abbe Refractometer Centrifuge Melting point machine Balance Distillation Apparatus Autoclave & Sterilizer Mixer, Stirrer & Shaker PH & Conductivity Meter Vacuum Blood Tube Hemoglobinometer, Hemocytometer & Colonometer Water Bath,Oil &Dry Bath Telescope Titrator, Ion Meter & D.O.ANALYZER Muffle Furnace Sample Concentration Flame Photometer Biological Safety Cabinet Laminar Flow Cabinet

Catalog and Manual

Catalog

Download E-catalog

Require Original Catalog

Require E-manual


image
Flame Photometer arrow Flame Photometer

FP6410  Flame Photometer

 
Specifications:
A lot of new technology and new materials are adopted. Such features as LCD display, menu-type instruction operation, curve storage, flameout protector and outside printout are enabled by the application of top grade embedded mono-chip computer circuit.
FP-6410
Specification: 
Range K: 0~999.9
Na: 0~999.9
Li: 0~999.9(Optional)
Sensitivity K: 0.2ug/mL
Na: 0.2ug/mL
Linearity K: 0.2ug/mL
Na: 0.7ug/mL
Drift less than 3% within 15s
Reproducibility 3%
Aspiration rate <6mL/min
Fuel supply L.P.G.
 
Working conditions:
1
Envirmental temperture: 10 Deg.C~35 Deg.C
2
Relative humidity: <85%
3
The instrument should be placed horizontally, avoiding direct sunshine radiation. There is no disturbance of strong electromagnetic field or vibration.
4
Fire extinguishing device should be equipped in the application field and good aeration should be guarznteed. Power supply: 220V +/- 22V, frequency 50Hz +/- 1 Hz, with good grounding.
 
FP6410
Standard Configuration:
1
Main Instrument 1 PC
2
Power Cable 1 PC
3
Chimney 1 PC
4
Clearing rod 2 PC
5
Air compressor 1 PC
6
Printer SP-T 2425SK 1PC
  
 
Optional accessories
1
Printer SP-T 2425SK
2
Air compressor
3
Lithium filter
Download E-Manual: http://www.hinotek.com/dmdocuments/manual/flame-photometer/Hinotek-FP6410-Flamephotometer-manual.pdf
 
  
  
  

FP-640 Flame Photometer

Characteristics
* FP-640 flame photometer is an improved instrument based on the original model. 
* A digital display to show clear measurement results. Improved gas path system suitable for various fuels, easy to operate and with stable readings. 
* It meets the requirements of medical clinical test. In addition to new added functions of testing high contented K and Na, it has the detection function of Li salt taken by the mental patients.
* Complete set including a main instrument, an air compressor, accessories and spare parts
FP-640
Specifications:
Range K:0~199
Na:0~199
Li:0~199 (Optional)
Sensitivity K:0.2μg/mL
Na:0.2μg/mL
Linearity K:0.2μg/mL
Na:0.7μg/mL
Drift less than 3% within 15s
Reproducibility 3%
Aspiration rate <6mL/min
Fuel supply Gasoline or L.P.G.
 
FP640
Standard Configuration:
1. Main Instrument 1PC
2. Power Cable 1PC
3. Air compressor 1PC
4. Glass Jar 2PC
5. Petrol gasify cylinder 1PC
 
 
Optional Accessories
1. Air compressor
2. Lithium Filter
 Download E-Manual: http://www.hinotek.com/dmdocuments/manual/flame-photometer/Hinotek-FP640-Flamephotometer-manual.pdf
 
 
 

FP6510 Flame Spectrophotometer

General Features:
1) The instrument is capable of measuring three elements at the same time among five elements including Na, K, Li, Ca and Ba;
2) The series of product is comprehensive and the end user can use it directly with preparing gas source of propane, butane and petroleum gas only;
3) Application areas: beverage, chemical manufacturing, clinical detection, agriculture, food detection, mineral extraction, oil industry, petroleum, chemical industry and soil analysis.
 
Structural Characteristics:
1) Five filters (Na, K, Li, Ca, and Ba) are equipped with five-channel detection function. Three elements can be detected at the same time and the content of three elements can be displayed as well.
2) The touch panel has number keys.
3) Single point calibration. The calibrated curve can be saved in the device.
4) RS232 interface. The device is able to connect extension equipment, such as, computer and printer.
5) A mist separator is provided.
 
Technical Characteristics:
1) Linear processing: each of the five elements can be processed with the application software; and single point calibration is prepared.
2) Sample injection rate: 4-6ml/min
3) The best measurement range:
 Na: 0 - 100ppm;
 K: 0 - 100ppm;
 Li: 0 - 100ppm;
 Ca: 0-1000ppm;
 Ba: 0 - 3000ppm;
4) Repeatability: when the equipment is stable for about 30mins, the deviation factor is not higher than 3% (the concentration of sample is 100ppm or even less);
5) Detection limit:
 Na: 0.01ppm;
 K: 0.01ppm;
 Li: 0.025ppm;
 Ca: 0.1ppm;
 Ba: 10ppm;
6) Time stability: less than 15s (after the sample is burnt in the flame);
7) Drifting: ≤3% (when the equipment is stable for about 30mins);
8) Linear: better than the median value of optimal result by 2% (single point calibration);
9) Two linear calibration methods: subsection method, and quadric fitting method;
 
Download E-Manual: http://www.hinotek.com/dmdocuments/manual/flame-photometer/Hinotek-FP640-Flamephotometer-manual.pdf
 
 
:
pic
email to us