HI-11228BBC86 Class II Biological Safety Cabinet |  | | Product Description | | HI-11228 BBC 86 is a NSF49 certified biological safety cabinet. Biobase is the only factory passed American NSF standard. | | | | Advantage: | | 1. VFD Display | | Compared with LED, LCD, it shall demonstrate various colors with high bright, even in the evening. It shall work no less than 30, 000 hours continually. | | 2. Negative pressure plenum surrounds contaminated positive pressure plenum; No fabric bags are used. | | 3. One-piece removable worksurface easy to clean. | | 4. Frameless sash, easy to clean. | | 5. Filter, Blower and Fluorescent lamp working time check. | | | | | | According to the performance criteria: | | 1 US Standard ANSI/NSF49: 2002 | | 2 European Standard EN12469: 2000 | | 3 Chinese Standard YY0569-2005 | | | | | | Certificates: | | ISO9001, ISO14001, ISO13485, CE, NSF49, MET | | | | Optional Accessory | | 1. Exhaust system (exhaust collar, exhaust blower and duct) | | 2. Air curtain tester | | 3. Formalin Fumigation sterilizer and Ammonnium Hydrogen Carbonate Neutralizer(filter changing tools) |
| | | | Spec: | | Model | HI-11228 BBC86 | Nominal Size | 1.2 meters(4' ) | | External Dimension(W*D*H) | 1421*850*2180mm(55.9" * 33.4" * 85.8") | Internal Size (W*D*H) | 1220*665*650mm (48" *26.1" * 25.6") | | Motors | One ECM motor | | Speed adjustable, high efficiency and low power consumption | | 110V & 220V acceptable | | Average Airflow Velocity | Inflow: 0.53±0.025m/s(105fpm) | Base Stand | Height: 630mm(24.9¡± ) | | Downflow: 0.33±0.025m/s(66fpm) | Made up of Ø239 rectangular steel tube | | Airflow Volumetubem()iaanlocitytected Aeratrol | Inflow: 465m 3 /h(275cfm) | Electrical Outlet | One, water proof type | | Downflow 67%: 956 m3/h (571cfm) | Five holes, 500W | | Exhaust 33%: 465 m3/h (275cfm) | On the right wall of the workarea | | Safety Opening Height | 200mm(8") | Petcock | Two (air, gas vacuum) | | UV | 30W germicidal UV lamp | | Emission of 253.7 nanometers for most efficient decontamination | | Cabinet Construction | Work area: 1.5mm304 Stainless Steel | | Frame: cold-roll steel sheets with electrostatic coating | | HEPA filter efficiency | > 99.999 for particle size above 0.3 microns | Noise | <63dB(A) | | Filter Guard Type | Aluminium Alloy | Fluorescent lamp Intensity | > 650Lux | | Ground Resistance | <0.1Ω | Voltage Resistance | 2 seconds no breakdown with DC1200V | | Electrical | AC 110V±10%, 60Hz±1Hz | | Full load Amps: 9A | | BTU/Hr: 1689 | | Standard Accessory | Spare UV lamp | | Power cord (5 meters) | | Fuse tube(six) | | Power Key |
| | | | Air Pattern and Protected Area: |  | | |
|
: |
|
|